LG LAN090HSV5
Air Conditioner
2 documents36 error codes2 service modes
Available documentation
Service Manual
- Air Conditioner Service Manual184 pg
- Room Air Conditioner SVC MANUAL(Exploded View)20 pg
MyPros+ Max
Diagnose your LG LAN090HSV5.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (36)
CodeMeaning
CH01Indoor unit room temperature sensor open/short error.CH02Indoor unit inlet pipe sensor open/short error.CH03Wired remote control communication error.CH04Float switch error (optional drain pump/float switch fault).CH05Communication error between indoor and outdoor units.CH06Indoor unit outlet pipe sensor open/short error.CH09Indoor unit EEPROM error (option PCBA poor connection).CH10Indoor unit BLDC motor fan lock (faulty motor operation).CH12Indoor unit middle pipe sensor open/short error.CH21DC Peak / IPM FaultCH22AC input current is higher than the limit (Max CT).CH23DC Link voltage low or high.CH26DC compressor position error.CH27PSC FaultCH29Compressor phase over-current.CH32High temperature in discharge pipe of the inverter compressor.CH34High pressure sensor reading is high.CH35Low pressure sensor reading is low.CH36Refrigerant leakage detection.CH37Exceed the compression ratio limit.CH38Refrigerant leakage detection (alternate code for CH36).CH40Inverter CT sensor open/shortCH41Inverter discharge temperature sensor open or short.CH42Low pressure sensor open/short.CH43High pressure sensor open/short.CH44Outdoor air temperature sensor open or short.CH45Outdoor heat exchanger (condenser middle pipe) sensor open or short.CH46Compressor suction temperature sensor (S-Pipe) open or short.CH48Outdoor sensor (condenser middle pipe) open or short (alternate designation).CH51Excess capacityView all 36 error codes
CH53Communication error between indoor and outdoor units.CH61High temperature in condenser pipe.CH62High temperature in outdoor PCBA heat sink.CH67Outdoor BLDC motor fan lock (faulty motor operation).CH72Detect 4-way valve transfer failure.CH93Communication error between indoor and outdoor units (alternate code).
Service modes (2)
- Forced Operation (Manual Operation without Remote Control)["Press the ON/OFF button on the display PCB or side of indoor unit to start operation."]
- Test Run Mode["Method 1
Full entry steps, exit procedures, and test sequences are available in Max.