mypros+
Error code reference

LG Air Conditioner Error Code CH62

High temperature in outdoor PCBA heat sink.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH62 error code actually means

The CH62 error means the outdoor unit's control board is getting too hot and has shut down to protect itself. This can happen because the unit is blocked, the fan isn't spinning, or the area around the outdoor unit is too confined for proper airflow. The system needs to cool down and the underlying cause needs to be addressed before it will run normally again.

Diagnostic procedure

The full CH62 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check installation location of outdoor unit; check fan locking; remove blockings around heat exchanger and filter; check PCBA heat sink screw connection.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH62 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH62

Ranked by how often they cause this code
  1. 1Restricted airflow around outdoor unit
  2. 2Outdoor fan motor locked or failed
  3. 3Blocked heat exchanger or filter
  4. 4Loose PCBA heat sink screws
  5. 5Poor installation location with high ambient temperature

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH62

What does CH62 mean on a LG air_conditioner?
CH62 means the outdoor unit's PCBA heat sink has exceeded its maximum allowable temperature. The control board monitors heat sink temperature to protect the inverter and power components from heat damage. When the threshold is exceeded, the system shuts down and displays CH62 until the root cause is corrected.
Is it safe to run my LG air conditioner with a CH62 error?
No, you should not continue operating the unit with an active CH62 error. The system has shut down automatically to protect the control board and inverter components from heat damage. Running the unit repeatedly under these conditions can permanently damage the PCBA, turning a straightforward repair into a costly board replacement.
How much does it cost to repair a CH62 error on an LG air conditioner?
If the fix involves clearing obstructions or tightening heat sink screws, the repair may cost nothing beyond a service call fee, which typically ranges from $75 to $150. A failed outdoor fan motor replacement generally runs between $150 and $400 including parts and labor. If the PCBA itself has been damaged by the overheating event, board replacement can range from $300 to $700 or more depending on the unit model.
How do I fix a CH62 error on my LG air conditioner?
Start by checking the outdoor unit for physical obstructions blocking airflow, including vegetation, fencing, or debris on the coil and filter. Confirm the outdoor fan is spinning freely and operating when the unit runs. If airflow appears normal, inspect the heat sink mounting screws on the outdoor control board and tighten any that are loose. If the fan motor is seized or the control board shows signs of damage, those components will need to be replaced.
Will resetting the unit clear the CH62 error?
A power reset may temporarily clear the fault and allow the unit to restart, but CH62 will return if the underlying cause is not resolved. The heat sink temperature fault is a protective response to a real condition, not a random glitch. Address the airflow, fan, or heat sink hardware issue first, then reset the unit.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass