LG Hvac Error Code 25
Low voltage or high voltage feeding unit.
Low voltage or high voltage feeding unit.
First step from the service manual
Verify proper 208/240V AC feeding unit; voltage feed must be 193-253V AC.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 25.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 25 means on a LG hvac
Error code 25 on an LG HVAC unit indicates that the supply voltage feeding the unit has fallen outside the acceptable operating range. The unit requires 208/240V AC single-phase power, and the acceptable voltage window is 193V AC on the low end to 253V AC on the high end. When the incoming voltage drops below 193V or rises above 253V, the control board detects the out-of-range condition and triggers this fault to protect the system from damage.
Low voltage conditions are more common than high voltage events and typically result from undersized wiring, loose connections at the disconnect or breaker panel, an overloaded electrical circuit, or utility supply issues. High voltage faults are less frequent but can occur during utility irregularities or if the unit has been connected to an incorrect power source. Either condition can cause compressor stress, control board instability, and premature component failure if left unaddressed.
The first diagnostic step is to measure the actual supply voltage at the unit's power terminals while the system is running under load, since voltage can appear acceptable at the breaker panel but sag significantly at the unit due to wiring resistance or loose terminations. A digital multimeter should be used to confirm the reading falls within the 193 to 253V AC range before attempting any other diagnostics.
Source: manufacturer service documentation.
Common causes of 25
- 01
Low supply voltage due to undersized or degraded wiring
Part replacementWire gauge that is too small for the circuit run length causes voltage to drop under load. Check wire size and measure voltage at the unit terminals while the system is actively running.
- 02
Loose or corroded electrical connections
Wiring / connectionLoose terminals at the disconnect box, breaker, or unit power block create resistance that causes voltage drop. Inspect and tighten all connections at the disconnect, panel, and unit terminals.
- 03
Utility supply voltage outside acceptable range
Wiring / connectionThe utility grid itself may be delivering low or high voltage to the property, which is outside the homeowner's control. Measure voltage at the main panel and contact the utility provider if readings are consistently out of range.
- 04
Overloaded circuit shared with other high-draw appliances
Part replacementIf the HVAC circuit is shared with other large loads, simultaneous operation can pull voltage below 193V. Verify the unit is on a dedicated circuit sized for its rated amperage.
- 05
Faulty or tripping breaker causing voltage irregularity
Part replacementA breaker that is weak or partially tripped can deliver inconsistent voltage rather than cutting power completely. Test breaker output under load and replace if voltage is unstable or below spec.
Frequently asked questions about 25
What does 25 mean on a LG hvac?
How do I fix error code 25 on my LG HVAC unit?
Is error code 25 on an LG HVAC a safety concern?
Will resetting the LG HVAC unit clear error code 25?
How much does it cost to repair error code 25 on an LG HVAC unit?