LG Hvac Error Code 42
Low pressure switch opened, under 14 PSI.
Low pressure switch opened, under 14 PSI.
Get the full diagnostic procedure for 42.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 42 means on a LG hvac
Error code 42 on an LG HVAC system indicates that the low pressure switch has opened, meaning refrigerant pressure on the low side of the system has dropped below 14 PSI. The low pressure switch is a safety device that monitors suction-side pressure and cuts system operation when pressure falls to an unsafe level. When the switch opens, the system shuts down the compressor to prevent damage from running under low refrigerant charge or restricted flow conditions.
The most common reason for suction pressure to fall below 14 PSI is an insufficient refrigerant charge, often caused by a leak somewhere in the refrigerant circuit. Low outdoor ambient temperatures can also cause low suction pressure, as can a blocked or dirty filter that restricts airflow across the indoor coil. A failing expansion valve or a restriction in the refrigerant line can similarly starve the low side of the system and trigger this threshold.
Diagnosing this fault requires connecting manifold gauges to the service ports and measuring actual system pressures. If static pressure confirms a low charge, the system must be leak-checked before adding refrigerant. A technician should inspect the TXV or expansion device, check filter and coil conditions, and confirm ambient temperatures are within the system's rated operating range. Resolving the root cause is essential before resetting the fault and returning the unit to operation.
Source: manufacturer service documentation.
Common causes of 42
- 01
Low refrigerant charge due to a leak
Part replacementA refrigerant leak reduces suction-side pressure below the 14 PSI threshold that triggers the low pressure switch. Leak detection using UV dye or an electronic leak detector is required to locate the source before recharging.
- 02
Dirty or clogged air filter
Part replacementA severely restricted air filter reduces airflow across the evaporator coil, causing the coil to over-cool and refrigerant pressure to drop. Inspect and replace the filter as a first physical check.
- 03
Faulty or stuck expansion valve (TXV)
Part replacementA malfunctioning thermostatic expansion valve that is closed or stuck will restrict refrigerant flow into the evaporator, causing low-side pressure to fall sharply. Pressure readings at the manifold gauges will help confirm abnormal superheat values pointing to this component.
- 04
Low outdoor ambient temperature
Wiring / connectionOperating the system in outdoor temperatures below its rated minimum can cause refrigerant to condense more than expected, reducing suction pressure and tripping the low pressure switch. Check whether the fault occurs only during cold weather conditions.
- 05
Faulty low pressure switch
Part replacementThe low pressure switch itself may be defective and opening prematurely even when system pressure is within the acceptable range. This can be confirmed by measuring actual system pressures with gauges while the switch has opened.
Frequently asked questions about 42
What does 42 mean on a LG hvac?
Can I fix error code 42 on my LG HVAC myself?
Is error code 42 on an LG HVAC dangerous?
Will resetting my LG HVAC clear error code 42?
How much does it cost to repair error code 42 on an LG HVAC?