Maytag Dryer Error Code PUSH

Amount to start has been inserted; make temperature selection.

Amount to start has been inserted; make temperature selection.

MyPros+ Max

Get the full diagnostic procedure for PUSH.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What PUSH means on a Maytag dryer

The PUSH indicator on a Maytag dryer is not an error code in the traditional sense. It is a status prompt that appears on coin-operated or metered Maytag dryer models to indicate that the required payment or activation amount has been inserted and the unit is now ready to begin a cycle. The display is essentially waiting for the user to complete the setup process by making a temperature selection before the start command can be executed.

This prompt is part of the dryer's cycle initiation sequence. On commercial or coin-operated Maytag dryer platforms, the control board monitors input from the payment or activation mechanism. Once the correct input is received, the control logic advances to the next step in the startup sequence and displays PUSH to signal that the machine is primed and ready. The dryer will not start until a valid temperature setting is selected, which acts as a final confirmation input to the control board.

If the PUSH prompt appears but the dryer does not respond to temperature selection inputs, the issue may lie with the selector switch, the control board, or a wiring fault between these components. In a properly functioning unit, selecting a temperature setting should immediately allow the cycle to begin. Persistent display of this prompt despite correct user input warrants inspection of the temperature selector switch for continuity and the control board for signs of failure or poor connections.

Source: manufacturer service documentation.

Common causes of PUSH

  1. 01

    Normal operation prompt

    Wiring / connection

    The PUSH display is the standard ready state for coin-operated Maytag dryers after payment is accepted. No fault is present; the user simply needs to select a temperature setting to proceed.

  2. 02

    Faulty temperature selector switch

    Part replacement

    If the dryer displays PUSH but does not respond when a temperature is selected, the selector switch may have failed or lost continuity. Testing the switch with a multimeter for continuity across its terminals can confirm this.

  3. 03

    Control board communication fault

    Part replacement

    A malfunctioning control board may become stuck in the PUSH prompt state and fail to advance the cycle after a temperature selection is made. Inspect the board for burnt components or damaged connectors.

  4. 04

    Loose or damaged wiring connections

    Wiring / connection

    Poor connections between the temperature selector switch and the control board can prevent the dryer from registering a temperature input and advancing past the PUSH prompt. Inspect harness connectors for corrosion or looseness.

See the test procedure for each cause

Frequently asked questions about PUSH

What does PUSH mean on a Maytag dryer?
PUSH is a status prompt on coin-operated Maytag dryer models indicating that the required payment or activation amount has been accepted and the dryer is ready to start. The unit is waiting for you to select a temperature setting before it will begin the drying cycle. This is a normal part of the startup sequence and does not indicate a malfunction.
How do I get my Maytag dryer to start after the PUSH prompt appears?
After the PUSH prompt appears, simply select your desired temperature setting using the temperature selector control. The dryer should then begin the cycle automatically. If the dryer does not respond to your temperature selection, the selector switch or control board may need to be inspected.
Is the PUSH display on my Maytag dryer a safety concern?
No, the PUSH prompt is not a safety warning. It is a normal operational status message indicating the dryer is ready for a temperature selection. The dryer is designed to wait in this state before starting so the user can confirm their desired heat setting.
Will resetting my Maytag dryer clear the PUSH prompt?
Resetting the dryer by cutting power will clear the prompt, but the display will return to PUSH the next time the required payment or activation is entered. Since PUSH is part of the normal startup sequence, it does not need to be cleared. If the prompt is stuck and unresponsive, a reset may help rule out a temporary control board glitch before further diagnosis.
How much does it cost to repair a Maytag dryer that is stuck on the PUSH prompt?
If the issue is caused by a failed temperature selector switch, replacement parts typically range from around $20 to $75 depending on the specific model. A control board replacement is more costly, generally falling in the $100 to $300 range for parts alone. Adding professional labor costs, total repair costs can range from $75 to $400 or more depending on the component involved and local service rates.