Trane Furnace Error Code 4 Flash

High temperature limit fault

High temperature limit fault - open high limit (heat exchanger temperature too high, possibly caused by low airflow or fan failure), auxiliary limit (reverse flow), or rollout switch open.

First step from the service manual

Scroll User Interface to view Last 4 Faults to determine HIGH LIMIT, AUX LIMIT, or ROLLOUT OPEN; disconnect power and check filter/blower wheel cleanliness.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.