Error codes (12)
CodeMeaning
1 Flash (Red)Normal LitePort data transmission2 FlashRetries or recycles exceeded3 FlashInducer or pressure switch error4 FlashOpen limit switch or rollout switch5 FlashFlame sensed when no flame should be present.6 FlashLine reverse polarity7 FlashExternal gas valve circuit error8 FlashWeak flame9 FlashOpen inducer limit errorGreen Fast FlashNormal operation, call for heat present.Green Slow FlashNormal operation, no call for heat.Green/Red LEDs on continuouslyFuse open or internal control failure.Service modes (3)
- ECM-2 Troubleshooter Kit Diagnostic1
- Fault Code Recovery / DisplayOn power up, the last 4 faults (if any) will be flashed on the red LED automatically
- Fault Code ResetPower up the control with 'G' energized, then apply 'R' to the 'W1' terminal 3 times within 6…