Trane Furnace Error Code 6 Flash

Line polarity fault (voltage reverse polarity), ground fault (proper earth ground not detected), igniter fault (igniter circuit open or shorted)…

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 6 Flash error code actually means

A 6 Flash code on your Trane furnace means the control board has detected a serious electrical problem, which could be anything from a wiring issue at the power supply to a failed igniter that lights the burners. The furnace has shut down as a safety measure to prevent damage or a hazard. A technician will need to check the electrical connections and the igniter to find and fix the specific cause.

Diagnostic procedure

The full 6 Flash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Scroll User Interface to view Last 4 Faults; for polarity/ground errors connect voltmeter to white neutral wire and green earth ground; for igniter/triac errors disconnect igniter and check resistance (should be 11-18 ohms).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 6 Flash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 6 Flash

Ranked by how often they cause this code
  1. 1Failed hot surface igniter
  2. 2Reversed line polarity
  3. 3Missing or improper earth ground
  4. 4Shorted igniter circuit
  5. 5Faulty control board triac or high AC supply voltage

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 6 Flash

What does 6 Flash mean on a Trane furnace?
A 6 Flash code means the furnace control board has detected one of five electrical faults: reversed line polarity, a missing earth ground, an open or shorted igniter circuit, a triac voltage error, or AC supply voltage that is too high. The board stores the specific fault type in its fault history log, accessible through the user interface. Because the code covers multiple possible causes, reviewing the last four stored faults is the essential starting point for diagnosis.
Is a 6 Flash code on a Trane furnace a safety hazard?
Yes, some of the underlying causes are genuine safety concerns. Reversed line polarity and a missing earth ground are electrical hazards that should not be ignored or bypassed. The furnace correctly refuses to operate under these conditions to protect both the equipment and the occupants. Do not attempt to override the lockout without first correcting the root cause.
How much does it cost to repair a Trane furnace 6 Flash error?
Repair costs vary depending on the cause. Correcting a wiring polarity or grounding issue typically involves labor only, ranging from roughly 80 to 200 dollars. A hot surface igniter replacement, including the part and labor, generally runs between 150 and 350 dollars. If the control board itself has a failed triac and requires replacement, costs can range from 350 to 700 dollars or more depending on the board and labor rates in your area.
Can I fix a Trane furnace 6 Flash error myself?
Some causes are within reach of a confident DIYer. If the fault history points to a polarity or grounding error, checking and correcting the wiring at the supply disconnect may resolve it. Replacing a failed hot surface igniter is also a common DIY repair once the igniter resistance confirms it is out of the 11 to 18 ohm range. However, diagnosing a faulty control board triac or measuring and correcting high line voltage should be handled by a licensed technician.
Will resetting the furnace clear a 6 Flash error?
Resetting the furnace by cycling power may temporarily clear the fault display, but the code will return quickly if the underlying problem has not been corrected. The control board stores the fault in its history log, so even if the display resets, the fault record remains. Resetting without diagnosis is not a repair and can delay finding a potentially serious electrical fault.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass