Trane Furnace Error Code 5 Flash

Flame detect fault

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 5 Flash error code actually means

Your Trane furnace has detected a flame inside the burner when it should be completely off, which is a safety issue the furnace control system takes seriously. This usually means the gas valve is not closing all the way, allowing a small amount of gas to keep burning. The furnace will not operate normally until this condition is resolved.

Diagnostic procedure

The full 5 Flash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Disconnect electrical power to furnace; turn off gas supply and remove gas valve to inspect for moisture or debris in inlet gas screen.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5 Flash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5 Flash

Ranked by how often they cause this code
  1. 1Gas valve not fully closing
  2. 2Debris or moisture in the inlet gas screen
  3. 3Shorted flame sensor rod
  4. 4Shorted wiring in the flame sense circuit
  5. 5Failed furnace control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5 Flash

What does 5 Flash mean on a Trane furnace?
A 5 Flash code on a Trane furnace means the control board has detected a flame signal when no flame should be present. This is called a flame detect fault and is a safety lockout condition. It most commonly points to a gas valve that is not fully closing, but it can also be caused by a faulty flame sensor or shorted wiring in the flame sense circuit.
Will resetting the furnace clear a 5 Flash fault code?
Resetting the furnace by cutting power and restoring it may temporarily clear the fault, but the code will return if the underlying problem is not corrected. The control board will re-enter lockout as soon as it detects the abnormal flame signal again. A reset alone is not a fix and should only be used as part of a diagnostic process.
How much does it cost to repair a Trane furnace showing a 5 Flash code?
Repair costs vary depending on the failed component. A gas valve replacement typically runs in the range of $200 to $600 including parts and labor. A flame sensor is a much less expensive part, generally in the $20 to $80 range for the component, with labor added on top. Control board replacement is the most costly scenario, often ranging from $400 to $900 or more depending on the specific model.
Is a 5 Flash fault on a Trane furnace dangerous?
Yes, this fault should be taken seriously. If the gas valve is leaking and sustaining an unintended flame, it represents a combustion safety risk. Turn off the gas supply to the furnace and disconnect electrical power before performing any inspection. Do not attempt to bypass or ignore this fault code.
How do I fix a 5 Flash error on a Trane furnace?
Start by disconnecting power and shutting off the gas supply, then remove the gas valve to inspect the inlet gas screen for moisture or debris. If the screen is contaminated, clean or replace the valve. If the valve is intact, inspect the flame sensor ceramic for cracks and check the sensor wiring for shorts to ground. If all components test properly, the control board may need replacement.