Trane Furnace Error Code Green Continuous / Red Flashing

Gas valve miswired or flame signal present at a call for heat.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the Green Continuous / Red Flashing error code actually means

Your Trane furnace has detected something unusual with the flame or gas valve wiring before it even tries to start a heating cycle. This could mean the wires on the gas valve are connected incorrectly, or the furnace thinks it sees a flame when there should not be one. This is a safety issue that should be inspected by a technician before the furnace is operated.

Diagnostic procedure

The full Green Continuous / Red Flashing procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check gas valve wiring connections and verify no flame signal is present before call for heat.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Green Continuous / Red Flashing procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Green Continuous / Red Flashing

Ranked by how often they cause this code
  1. 1Gas Valve Miswiring
  2. 2Flame Sensor Short or Grounding Issue
  3. 3Damaged Flame Sensor Lead Wire
  4. 4Control Board Fault
  5. 5Wiring Disturbed During Service or Installation

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Green Continuous / Red Flashing

What does Green Continuous / Red Flashing mean on a Trane furnace?
This LED pattern indicates that the control board has detected either a miswired gas valve or a flame signal present before a call for heat has begun. Both conditions represent an out-of-sequence event in the ignition circuit. The furnace will not operate normally until the underlying wiring or sensor issue is resolved.
Is it safe to run my furnace when it shows this error code?
No, you should not attempt to operate the furnace while this fault is active. A miswired gas valve or an unexpected flame signal represents a safety risk, as it indicates the ignition sequence is not functioning as designed. The furnace should remain off until the cause is identified and corrected.
How much does it cost to repair a Trane furnace showing this error?
Repair costs depend on the root cause. If the issue is simply a miswired gas valve connection, a service call diagnostic fee may be the primary cost, typically ranging from $75 to $150. If a flame sensor or lead wire needs replacement, parts are generally low cost, but total repair costs including labor can range from $100 to $300. Control board replacement, if required, is the most expensive scenario and can range from $300 to $600 or more depending on the model.
Can I fix a Green Continuous / Red Flashing error on my Trane furnace myself?
A knowledgeable DIYer can inspect the gas valve wiring connections and compare them to the wiring diagram on the furnace cabinet for obvious miswiring. However, diagnosing a faulty flame sensor or a shorted lead wire requires a multimeter and familiarity with furnace control circuits. Because this fault involves gas valve wiring, it is recommended to have a qualified technician confirm the repair before operating the furnace.
Will resetting my Trane furnace clear the Green Continuous / Red Flashing code?
A power reset may temporarily clear the displayed code, but the fault will return as soon as the control board detects the same condition again. Because this error is caused by a wiring or component issue rather than a momentary glitch, resetting alone will not resolve it. The underlying problem with the gas valve wiring or flame sensor circuit must be corrected first.