mypros+
Error code reference

Trane Furnace Error Code None (ID MTR ERR)

Blower HP/OEM does not match Personality Module data.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the None (ID MTR ERR) error code actually means

Your Trane furnace has detected that the blower motor installed in the system does not match the settings stored in its control module. This usually means the wrong motor was installed, or the control module has the wrong information programmed into it. The furnace will not operate normally until this mismatch is corrected.

Diagnostic procedure

The full None (ID MTR ERR) procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock None (ID MTR ERR) procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of None (ID MTR ERR)

Ranked by how often they cause this code
  1. 1Replacement blower motor with incorrect HP rating
  2. 2Incorrect or incompatible Personality Module
  3. 3Wrong motor type installed
  4. 4Personality Module data corruption
  5. 5Motor communication wiring fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about None (ID MTR ERR)

What does None (ID MTR ERR) mean on a Trane furnace?
The ID MTR ERR fault means the furnace control system has detected that the installed blower motor's horsepower or type does not match the configuration data stored in the Personality Module. The Personality Module holds programmed parameters for the furnace, and any discrepancy between those parameters and the actual motor triggers this error. The furnace will not operate correctly until the motor and Personality Module data are brought into alignment.
Is it safe to run my furnace with the ID MTR ERR code showing?
The furnace is designed to prevent normal operation when this fault is active, which means heating output will be limited or unavailable. Attempting to force operation with a mismatched motor risks running the blower outside its intended parameters, which could cause motor damage or inadequate airflow. It is best to have the fault diagnosed and corrected before relying on the furnace for heating.
How much does it cost to repair the ID MTR ERR fault on a Trane furnace?
Repair costs vary depending on the root cause. If only a wiring connector needs attention, costs may be limited to a service call fee, typically in the range of $75 to $150. If the blower motor needs replacement, parts and labor could range from $300 to $700 or more. Personality Module replacement or reprogramming adds additional cost, often in the $100 to $300 range depending on the technician and part availability.
Can I fix the ID MTR ERR fault myself on a Trane furnace?
Some basic checks, like inspecting motor wiring and connectors, can be done by a knowledgeable homeowner. However, confirming motor HP ratings, identifying the correct Personality Module configuration, and reprogramming or replacing the module typically requires a qualified HVAC technician with access to the proper equipment and Trane system specifications.
Will resetting my Trane furnace clear the ID MTR ERR code?
A reset will not permanently clear this fault if the underlying mismatch between the blower motor and the Personality Module data has not been resolved. The error will return at the next startup cycle when the control board re-reads the motor identity. A lasting fix requires correcting the hardware or reprogramming the Personality Module to match the installed motor.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass