Model reference

Amana 13-3N

Air Conditioner

1 document63 error codes11 service modes

Available documentation

Tech Tip

  • Instruction Sheet - 85288342 pg
    Covers this model
MyPros+ Max

Diagnose your Amana 13-3N.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (63)

View all 63 error codes
8-2Drain motor electrical problem8-3Drain stuck on9-1Diverter can't find position9-2Diverter stuck on9-3Diverter disk missingF0 E0No error(s) foundF1 E0EEPROM communications error.F1 E1EEPROM checksum failure.F1 E2UL A/D error(s).F1E1Indicates a Cycle Control Unit (CCU) problem.F2 E0Shorted key / Stuck key.F2 E1Keytail unplugged.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2UI cannot read EEPROM software from the User Interface.F3 E0Oven sensor shorted.F3 E1BAKE/BROIL range over temperature.F3 E2CLEAN range over temperature.F3 E3Oven sensor opened.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; occurs if the P4/P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F5 E0Door latch and switches do not agree.F5 E1Door latch not operating.F5 E2Latch error during CLEAN.L2Low L2 voltage (less than 50V) detected at installation.PFPower failure occurred while the dryer was running.

Service modes (11)

  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the Dry Level button for at…
  • Error Code History DisplayEnter Service Diagnostics Cycle (1-2-3-1-2-3-1-2-3)
  • Install Diagnostics["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
  • Last fault code displayPress and hold CANCEL/OFF key for 5 seconds
  • Rapid Advance ModePress HI TEMP
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
  • Service Diagnostics CycleWhile in standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…
  • Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
  • Temperature Adjustment (Calibration)Press and hold BAKE pad for 5 seconds
  • Test mode (diagnostic)Within 60 seconds of power up, simultaneously hold down the BAKE and CLOCK keys for 5 seconds
  • User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…

Full entry steps, exit procedures, and test sequences are available in Max.