Model reference

Amana CR2-1

Air Conditioner

28 error codes4 service modes
MyPros+ Max

Diagnose your Amana CR2-1.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (28)

CodeMeaning
AXIAL PROBE FAULTProblem with the axial temperature sensor circuit.BURNER CONTROL FAULTGas return valve signal did not turn on before DSI purge time expired or turned…BURNER HIGH-LIMIT FAULTBurner high-limit switch opened during the cycle while heat was on.BURNER PURGE FAULTGas return signal detected before the heat signal was sent out by the…CHECK CONTROL BOARD FUSE #2Main fuse (fuse 2) on the Phase 7 controller board has opened, preventing cycle…CLEAN LINTLint drawer has not been opened/cleaned within the programmed Lint Cleaning…DISCONNECTED WATER VALVES.A.F.EdoorDoor switch circuit is opendSFLDryer sensor circuit failureEXHAUST HIGH TEMP FAULTTemperature sensor detected overheating with steady increase to a known upper…EXHAUST HIGH-LIMIT FAULTTumbler safety over-temperature switch has opened.EXHAUST PROBE FAULTProblem with the exhaust temperature sensor circuit.FLAME FAULTGas valve return signal was lost anytime after the DSI proof time, occurring…HotOverheating conditionIGNITION FAULTGas valve return signal was lost during the DSI proof time and retry count has…LINT ACCESS OPENLint drawer is open and needs to be closed.MAIN DOOR OPENEDMain door is open when it should be closed.MODEL ERROR, ENTER CORRECT MODELController detected unexpected input signals (sail switch, gas valve) that do…OPEN THERMISTOR PROBES.A.F.EROTATION SENSOR FAULTTime between rotational sensor pulses exceeded 10 seconds, indicating tumbler…S.A.F.E. SYSTEM ACTIVATEDController has detected a fire condition and is currently extinguishing the…S.A.F.E. SYSTEM WAS ACTIVATEDController detected a fire condition and has completed the extinguishing…SAIL SWITCH CLOSED FAULTSail switch is in the closed position prior to starting; switch did not open…SAIL SWITCH OPEN FAULTSail switch did not close within 8 seconds of starting a cycle, or opened for…SEFLRotational sensor circuit failureSHORTED THERMISTOR PROBES.A.F.ESHORTED WATER VALVES.A.F.EWATER NOT CONNECTEDNo water pressure at the S.A.F.E

Service modes (4)

  • Operational Service Check1. Turn on electric power to the dryer. 2. Display will read 'FILL.' 3. Press 'E' on the keyboard…
  • Operational Service Check Procedure["Turn on electric power to the dryer.","Display will read 'FILL'.","Press 'E' on the keyboard…
  • Phase 5 OPL System DiagnosticsDiagnostics are automatic
  • S.A.F.E. System DiagnosticWhen display shows 'S.A.F.E

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax