Model reference
Amana VBC30CT-1J/P54878-21C
Air Conditioner
3 documents26 error codes10 service modes
Available documentation
Service Manual
- Service Manual - RS510000141 pg
Installation Guide
- Installation Instructions67 pg
- Installation Instructions34 pg
MyPros+ Max
Diagnose your Amana VBC30CT-1J/P54878-21C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (26)
CodeMeaning
2EVoltage for motor control bus is over or under specified limit.3EOver Current is detectedbEMotor tach signal exists without motor running (tach signal exists without…dcNever exceeded 400 rpm due to an unbalanced load during final spin.dLOpen door lock switch with motor running.dSDoor switch is read as open and the door locked switch is read as locked.E0Keypad not connected, or key held down too long, or key is shortedE1Temperature sensor opened (when displayed on upper/left side) or temperature…E2A key is sensed to be pressed more than 30 seconds; the key will be assumed to…E3Machine control is attempting to drive the motor but is not seeing any tach…F0Default F codeF1Electronic control malfunction (when E code is not E3); or keypad not connected…F2Door latch error during Self-CleanF3Temperature sensor opened (E0) or temperature sensor shorted (E1).F5Oven temperature too highFLDoor failed to lock after 3 attempts.HrHeater Relay failure.LEWater sensor level faultLODoor failed to unlock after 3 attempts.ndThe water level fails to drop below the Low Water level reset within 15…nFContinuous fill of 12 minutes or total fill of 14 minutes detected.odThe door has not been opened after two complete wash cyclesOEA fault is detected in the water level sensorSrSystem Relay failureSudSWasher is in a suds period in the cycle; displayed instead of time remaining.tEAbnormal high/low temperature or ohm resistance seen from sump thermistor.Service modes (10)
- Board Input TestWhile in Service Mode, press the Spin Only key
- Board Output TestWhile in Service Mode, press the Spin Speed key.
- Diagnostic Code DisplayWhile in Service Mode, press Rinse & Spin key (display shows 'd'), then rotate Rotary Cycle…
- Display Diagnostic CodesWhile in Service Mode, press Rinse & Spin key (display shows 'd'), then rotate Rotary Cycle…
- Electronic Oven Control Test["1. Unplug the oven.","2. Remove the cabinet.","3. Discharge the HV capacitor with a 20,000 ohm…
- Fast Time Down TestWhile in Service Mode and while any test or cycle is running, press Wash/Rinse Temp key to advance…
- LED/Switch TestWhile in Service Mode, press the Delay key for 3 seconds, then press individual buttons to test
- Quick Service CycleWhile in Service Mode, press Wash/Rinse Temp and Soil Level keys for 3 seconds
- Quick Spin TestWhile in Service Mode, press Delay and Rinse & Spin keys.
- Service Mode1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana air conditioner models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass