Model reference
Amana OC-100/P96235-1F
Furnace
2 documents36 error codes7 service modes
Available documentation
Tech Sheet
- Whirlpool Amana WED9050XW NED7300WW1 Electric Dryer Tech Sheet Tech Sheet W1023879512 pg
Installation Guide
- Installation Instructions104 pg
MyPros+ Max
Diagnose your Amana OC-100/P96235-1F.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (36)
CodeMeaning
1-1Pilot relay K2 stuck on1-2Control software issue10-1Dispenser electrical problem10-2Vent wax motor electrical problem10-3Drying fan error2-1Stuck key detected2-2No response from User Interface3-1Thermistor/OWI open3-2Thermistor/OWI shorted3-3OWI failure or failed calibration4-1Wash motor problem4-2Motor communication error5-1Door stuck open5-2Door stuck closed6-1Low/no water (mechanical problem)6-2Fill valve electrical problem6-3Suds/air in pump6-4Float switch open6-6Cool water6-8Flowmeter or regen valve electrical problem7-1No heat7-2Heater stuck on8-1Slow drain8-2Drain motor electrical problem8-3Drain stuck on9-1Diverter can't find position9-2Diverter can't find position (additional instance or variant).9-3Diverter problem (variant).F1E1Primary control failure.F2E1Stuck button or user interface mismatch (only appears in service diagnostic…View all 36 error codes
F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E6Moisture sensor strip is open (only appears in service diagnostic mode).F3E7Moisture sensor strip has shorted (only appears in service diagnostic mode).F4E4Low line voltage detected.PFPower failure occurred while the dryer was running.
Service modes (7)
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the DRY…
- Error History ReadEnter Service Diagnostics Cycle (1-2-3-1-2-3-1-2-3)
- Rapid Advance Mode1. Start a cycle. 2. Press HI TEMP
- Sales Demo Mode ExitRun Service Diagnostics Cycle (1-2-3-1-2-3-1-2-3) to clear Demo mode.
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the DRY…
- Service Diagnostics Cycle1
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.