Amana OC80-B2
Furnace
2 documents21 error codes14 service modes
Available documentation
Tech Sheet
- techsheet-12728130.pdf4 pg
Service Manual
- Service Manual - RS120000280 pg
MyPros+ Max
Diagnose your Amana OC80-B2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (21)
CodeMeaning
F1Internal board failure (F1E0, F1E1, F1E2 on LCC 180/190).F1E1Indicates a CCU (Cycle Control Unit) problem.F2Shorted key / A/D Error(s) (F2E0 on LCC 180/190).F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3Oven sensor opened, oven sensor shorted, BAKE/BROIL range over temperature, or…F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5Door and switches do not agree during Clean mode (F5E0, F5E2 on LCC 180/190).F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F9Miswired house or miswired range (F9E0 on LCC 180/190).L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.Service modes (14)
- Customer-Focused Dryness Level Adjustment1
- Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
- Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press the following keypads to test individual control relays
- Electronic Testing Mode - Forced Compressor Start["Press Display On pad to activate control panel","Simultaneously press and hold Max Frz pad and…
- Electronic Testing Mode - Forced Defrost Start["Press Display On pad to activate control panel","Simultaneously press and hold Max Ref and…
- Forced Defrost (Program Mode B)["Enter Program Mode B","Press and hold Alarm Off pad for 3 seconds"]
- Forced Pulldown / Compressor Start (Program Mode B)["Enter Program Mode B","Press and hold Max Frz pad for 3 seconds"]
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Program Mode A["Open refrigerator door","Press Display On pad","Press * pad","Within 6 seconds press the…
- Program Mode B["Enter Program Mode A first (see Program Mode A entry sequence)","Toggle to Program Mode B by…
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Software Version Display1
- Temperature Adjustment1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass