Model reference
Amana OH-112
Furnace
8 documents48 error codes7 service modes
Available documentation
Tech Sheet
- Tech Sheet28 pg
- techsheet-rt4100029-rev2.pdf4 pg
- Tech Sheet - 128456364 pg
- Tech Sheet - 1602325110 pg
- Tech Sheet4 pg
- W10308611 Amana ABB2224DES Whirlpool GB2SHTXTB00 Refrigerator Tech Sheet2 pg
Service Manual
- ADC AD-410 Service Manual-PH7 Industrial118 pg
Installation Guide
- Installation Instructions7 pg
MyPros+ Max
Diagnose your Amana OH-112.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (48)
CodeMeaning
BAD PROBEIndicates the temperature probe is open or shorted.bFIce maker self-diagnosticsCALL FOR SERVICEIndicates a board communication failure between the display and I/O boards.CHECK CONTROL POWERIndicates control power is off.DRY ENABLE FAULTA signal from the PLC indicating the dryer is not level and/or all doors are…E1Ice maker self-diagnosticsE2Ice maker self-diagnosticsE3Ice maker self-diagnosticsE4Ice maker self-diagnosticsEE PROM FAULT ###Error in memory location; the ### indicates the specific location of the fault.EXHAUST HIGH LIMIT FAULTIndicates the 225°F (107°C) temperature disk in the exhaust has opened.EXHAUST HIGH TEMP FAULTIndicates the temperature in the basket (tumbler) exhaust is above 220°F…F1E3Microwave oven ACU (Appliance Control Unit) internal error.F3E0Main oven sensor open or shorted (open if temperature above 1112°F/600°C…F4E1Microwave cavity temperature sensor error (F3E0 will also appear one minute…F4E4Microwave oven humidity sensor error.F5E0Door switch and latch switch do not agree.F6E0Oven user interface lost communication.F6E1Oven temperature error (F3E0 will also appear on display).F6E4User interface / Appliance manager state status mismatch.F6E6Oven appliance manager lost communication.F9E0Product not wired correctly.FAN CONTACTOR FAULTThe fan contactor was not pulled in.FAN OVERLOAD FAULTIndicates the fan (blower) motor overload has tripped open.FRONT BURNER HIGH LIMIT FAULTIndicates the 330°F (166°C) temperature disk in the front burner has opened.FRONT BURNER IGNITION CONTROL FAULTFront DSI ignition module is not working or failure to ignite.FRONT BURNER PURGE FAULTThe front gas valve signal is present during the prepurge time when it should…FRONT BURNER VALVE FAULTIndicates the front gas valve is not working, no gas is turned on, or flameout…FRONT DOOR NOT CLOSEDA front door is open when it should be closed.FRONT NOT DOWNDryer is tilted back (front is not in the down/level position).View all 48 error codes
FRONT SAIL SWITCH CLOSED FAULTFront sail switch is closed when it should be open.FRONT SAIL SWITCH OPEN FAULTFront sail switch is open when it should be closed.LINT DRAWER OPENIndicates the lint drawer is open and needs to be closed.LOW VOLTAGE FAULTIndicates power has dropped below operating values and the dryer will shut down.MODEL ERRORThe wrong model was selected for the dryer; must enter correct model.OPThermistor is open, displayed during service test thermistor readings.PAIce maker self-diagnosticsREAR BURNER HIGH LIMIT FAULTIndicates the 330°F (166°C) temperature disk in the rear burner has opened.REAR BURNER IGNITION CONTROL FAULTRear DSI ignition module is not working or failure to ignite.REAR BURNER PURGE FAULTThe rear gas valve signal is present during the prepurge time when it should…REAR BURNER VALVE FAULTIndicates the rear gas valve is not working, no gas is turned on, or flameout…REAR DOOR NOT CLOSEDA rear door is open when it should be closed.REAR NOT DOWNDryer is tilted forward (rear is not in the down/level position).REAR SAIL SWITCH CLOSED FAULTRear sail switch is closed when it should be open.REAR SAIL SWITCH OPEN FAULTRear sail switch is open when it should be closed.ROTATION FAULTIndicates the basket (tumbler) is not rotating.SHThermistor is shorted, displayed during service test thermistor readings.TUMBLER OVERLOAD FAULTIndicates the basket (tumbler) motor overload has tripped open.
Service modes (7)
- Component Activation["Plug in oven or connect power.","Enter Diagnostics mode.","Touch or scroll to 'Component…
- Diagnostics Mode["Press 'Setting', scroll down and press 'Info.'","Press 'Service and Support.'","Verify model…
- Error Diagnostic["Enter Diagnostics mode.","Press 'Error Diagnostic' to see the last error detected."]
- Sensors & Switches["Plug in oven or connect power.","Enter Diagnostics mode.","Touch or scroll to 'Sensors &…
- Service Diagnostics Mode["On the Main (Eyebrow) UI, press and hold both temperature '-' buttons simultaneously for 3…
- System Info["Enter Diagnostics mode.","Select 'System Info'."]
- U.I. Configuration Mode["Press 'Setting', scroll down and press 'Info.'","Press 'Service and Support.'","Check that the…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands