mypros+
Model reference

Amana OH-168

Furnace

16 documents83 error codes39 service modes

Available documentation

Tech Sheet

  • techsheet-rt2230008.pdf10 pg
    Covers this model
  • Tech sheet35 pg
    Covers this model
  • Basic Operation of Commercial Stacked Washer/dryer20 pg
    Covers this model

Service Manual

  • ADC AD-410 Service Manual-PH7 Industrial118 pg
    Covers this model
  • Service Manual - RS222000160 pg
    Covers this model

Installation Guide

  • Installation Instructions72 pg
    Covers this model
  • Installation Instructions48 pg
    Covers this model
  • Installation Instructions100 pg
    Covers this model
  • Installation Instructions24 pg
    Covers this model
  • Installation Instructions56 pg
    Covers this model
  • Instrucciones de instalacion116 pg
    Covers this model
  • Installation Instructions64 pg
    Covers this model
  • Installation Instructions88 pg
    Covers this model
  • Installation Instructions56 pg
    Covers this model
  • Installation Instructions20 pg
    Covers this model
  • Installation Instructions32 pg
    Covers this model
MyPros+ Max

Diagnose your Amana OH-168.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (83)

View all 83 error codes
F 70Communication failure between CCU and UIC.F 71Dryer communication failure from UIC to dryer CCUF 73UIC failure (washer) / UIC Microprocessor error (dryer)F 74UIC EEPROM errorF01CCU (Central Control Unit) errorF04Accelerometer failureF11MCU (Motor Control Unit) errorF20No water detected entering washerF21Long drainF22Door lock errorF24Temperature sensor errorF25Tachometer errorF26Door switch errorF27Overflow conditionF28Communication failure between CCU and MCU.F29Door unlock errorF31Overheating of motorF33Pump disconnectedF34Load detected in washer during Washer Cleanout Cycle.F70Communication failure between CCU and UI (User Interface).F73UI failureF74UI failureFAN CONTACTOR FAULTThe fan contactor was not pulled in.FAN OVERLOAD FAULTIndicates the fan (blower) motor overload has tripped open.FRONT BURNER HIGH LIMIT FAULTIndicates the 330°F (166°C) temperature disk in the front burner has opened.FRONT BURNER IGNITION CONTROL FAULTFront DSI ignition module is not working or failure to ignite.FRONT BURNER PURGE FAULTThe front gas valve signal is present during the prepurge time when it should…FRONT BURNER VALVE FAULTIndicates the front gas valve is not working, no gas is turned on, or flameout…FRONT DOOR NOT CLOSEDA front door is open when it should be closed.FRONT NOT DOWNDryer is tilted back (front is not in the down/level position).FRONT SAIL SWITCH CLOSED FAULTFront sail switch is closed when it should be open.FRONT SAIL SWITCH OPEN FAULTFront sail switch is open when it should be closed.HIHigh line voltage detectedHOTMagnetron overheating condition detected.LINT DRAWER OPENIndicates the lint drawer is open and needs to be closed.LOLow line voltage detectedLOW VOLTAGE FAULTIndicates power has dropped below operating values and the dryer will shut down.MODEL ERRORThe wrong model was selected for the dryer; must enter correct model.PCE1Checksum errorPCE5Communication failure between high voltage board, low voltage board, or…PCE6Communication failure between high voltage board, low voltage board, or…REAR BURNER HIGH LIMIT FAULTIndicates the 330°F (166°C) temperature disk in the rear burner has opened.REAR BURNER IGNITION CONTROL FAULTRear DSI ignition module is not working or failure to ignite.REAR BURNER PURGE FAULTThe rear gas valve signal is present during the prepurge time when it should…REAR BURNER VALVE FAULTIndicates the rear gas valve is not working, no gas is turned on, or flameout…REAR DOOR NOT CLOSEDA rear door is open when it should be closed.REAR NOT DOWNDryer is tilted forward (rear is not in the down/level position).REAR SAIL SWITCH CLOSED FAULTRear sail switch is closed when it should be open.REAR SAIL SWITCH OPEN FAULTRear sail switch is open when it should be closed.ROTATION FAULTIndicates the basket (tumbler) is not rotating.S1Watchdog circuit detects a shorted membrane touch panel.SudSSuds detected during drainTUMBLER OVERLOAD FAULTIndicates the basket (tumbler) motor overload has tripped open.

Service modes (39)

  • Cycle Credit (Free Cycle)["Enter diagnostic mode (entire display flashing).","Press the HOT button (CC will display)."]
  • Diagnostic Mode["First enter Set-Up Mode (insert service switch key and turn counter-clockwise).","Press and hold…
  • Diagnostic Mode (Washer Diagnostic Mode)["First access the Setup Mode (Start Operating Set-up).","Press and hold the QUICK CYCLE button for…
  • Door Cycles and Magnetron Hours["1
  • Dryer Field Diagnostic Cycle (Diagnostic Sub-Mode)["Enter Diagnostic Mode (entire display flashing).","Press the upper middle (PERM PRESS) button."]
  • Extended Memory Board Test["1
  • H.V. System Test["1
  • H.V. System Test (within Service Test Mode)["1
  • Help Mode["Enter Set-Up Mode.","Press the lower left (HOT) button while in special pricing option 2.XX (or…
  • Help Mode (Aide Mode)["PD models
  • Help Mode (DA Communication Established)["Open the service door.","The message dAS will appear in the display.","Press the HOT button to…
  • Help Mode (dAS Mode)["Open the service door or insert a manual diagnostic card.","The message 'dAS' will appear in the…
  • Help Mode (Manual Communication)["Open the service door.","Press the WARM button until the set-up code 2.XX is displayed.","Press…
  • Help Mode (PD Models)["Open the service door.","Press the LOWER MIDDLE key pad until the display reads 2.XX.","Press the…
  • Manual Overview Test["Enter diagnostic mode (entire display flashing).","Press the COTTON/WHITES button."]
  • Option Programs (All Models Except WDYRC)["1
  • Programming Mode (DQ & MC models)["1
  • Programming Mode (RC models)["1
  • Quick Overview Test["Enter diagnostic mode (entire display flashing).","Press the WARM button."]
  • Quick Spin Cycle["Enter diagnostic mode (entire display flashing).","Press the PERM PRESS button."]
  • Quick Spin Program (Drain and Spin)["Enter Diagnostic Mode (display is flashing).","Press the COLORS button."]
  • Service Access Code (Code d'accès pour entretien)["Works only on washers configured for $0.00 sale price without Special Price, and Coin/Debit…
  • Service Access Code (key dance entry without console removal)["Washer must be set up for 0 vend price without Special Pricing, and Coin/Debit Option must be set…
  • Service Diagnostic Test Modes["Make sure power is turned off.","Remove the service door on metercase models, or remove the AA1…
  • Service Test Mode["1
  • Service Test Mode (All Models Except WDYRC)["1
  • Set-Up Mode (Coin Payment)["Insert service switch key and turn counter-clockwise."]
  • Set-up Mode (PD Models)["Insert service access door key, turn, and lift to remove service access door."]
  • Set-up Mode (PR Models via AA1 removal)["Unplug washer or disconnect power.","Open console, disconnect plug on AA1, close console.","Plug…
  • Setup Mode (Parameter Setting Mode)["PD models
  • Washer Cleaning Program["Enter Diagnostic Mode (display is flashing).","Press the BRIGHTS button."]
  • Washer Cleanout Cycle["Enter diagnostic mode (entire display flashing).","Press the COLORS/DELICATES button."]
  • Washer Cleanout Cycle (Diagnostic Sub-Mode)["Enter Diagnostic Mode (entire display flashing).","Press the center right (COLORS/DELICATES)…
  • Washer Cycle Credit (Diagnostic Sub-Mode)["Enter Diagnostic Mode (entire display flashing).","Press the lower left (HOT) button (CC will…
  • Washer Diagnostic Mode (via Key Dance - 9060 non-coin models with $0 vend price)["Key dance must be performed within 60 seconds.","Press Cottons/Whites button.","Press Cold…
  • Washer Diagnostic Mode (via Service Access Door)["Open the service access door on top of the metercase (9050 models
  • Washer Manual Overview Test Cycle (Diagnostic Sub-Mode)["Enter Diagnostic Mode (entire display flashing).","Press the center left (COTTON/WHITES) button."]
  • Washer Quick Overview Test Cycle (Diagnostic Sub-Mode)["Enter Diagnostic Mode (entire display flashing).","Press the lower middle (WARM) button."]
  • Washer Quick Spin Cycle (Diagnostic Sub-Mode)["Enter Diagnostic Mode (entire display flashing).","Press the center middle (PERM PRESS) button."]

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands