Model reference
Amana OH-84-DF/P96363-5F
Furnace
3 documents51 error codes21 service modes
Available documentation
Tech Sheet
- Tech Sheet - W11087920 - Rev A60 pg
- Tech Sheet whirlpool dryer W10606148 Rev C60 pg
- Tech Sheet - W10403269 - Rev A52 pg
MyPros+ Max
Diagnose your Amana OH-84-DF/P96363-5F.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (51)
CodeMeaning
drnDrain pump system problemF0E2Oversuds condition detectedF0E3Overload conditionF0E4Spin limited by water temperatureF0E5Off balance load condition detected.F1E1Main control fault (internal ACU failure).F1E2Motor control section of the main control has faulted.F1E3Mismatch of ACU and UIF2E1UI stuck buttonF2E2User Interface software errorF2E3UI mismatchF2E4UI software errorF2E5UI software errorF3E1Pressure system faultF3E2Inlet water temperature faultF3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1Heater stuck onF4E2Heater not turning onF4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5E1Lid switch faultF5E2Lid lock will not lock or lid lock failure.F5E3Lid lock will not unlock.F5E4Lid not opened between cyclesF6E1Communication error from UI to CCU; communication between the CCU and UI has…F6E2Communication errorView all 51 error codes
F6E3Communication errorF7E0Loss of powerF7E1Loss of power during spinF7E2Motor drive module failureF7E3Basket engaged during washF7E4Basket re-engagement failureF7E5Shifter failure.F7E6Motor circuit openF7E7Motor unable to meet target RPM.F7E8Motor over temperatureF7E9Locked rotorF8E1Long fillF8E3Overflow or flood conditionF8E6Water hazardF9E1Drain pump system problemF9E2Drain pump system problemFCE1WiFi Module communications lost.LLow L2 voltage (less than 50V) detected at the CCU; displayed on models 4000…L2Low L2 voltage (less than 50V) detected at the CCU.LFLong fillPFPower failure occurred while the dryer was running.
Service modes (21)
- Automatic Function TestWith door latched, press key pads in the following sequence within 10 seconds
- Component Activation / Quick Service Cycle (LCD in Door Models)["Enter Service Diagnostic Mode (LCD in Door) first.","From the DIAGNOSTICS HOME screen, scroll…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Fault Code Display / Clearing["Enter Service Diagnostic Mode.","If saved fault code exists, it will be flashing in the display…
- Fault Code Display and Clear["Activate Service Diagnostic Mode first.","Press and release the 3rd button to display saved fault…
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Key Activation & Encoder Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- Key Activation & Encoder Test (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Manual Function TestWith door latched, press key pads in the following sequence within 10 seconds
- Service Calibration["Enter Service Test Mode.","Select function number 052 using Soil Level/Temp buttons or cycle…
- Service Diagnostic Mode["Ensure washer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (Console Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (LCD in Door Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Open and close the…
- Service Diagnostics (Automated Test Cycle)["Enter Service Test Mode.","Select function number 051 using Soil Level/Temp buttons or cycle…
- Service Test Mode (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Service Test Mode (Load Control)["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- Software Version Display (Console Models)["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands