Model reference

Amana OH-125-3/P96236-6F

Furnace

55 error codes20 service modes
MyPros+ Max

Diagnose your Amana OH-125-3/P96236-6F.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (55)

CodeMeaning
:Flashing colon indicates a power failure has occurred.AFLow inlet air flow detected at install.E1Thermistor is open.E2Thermistor has shorted.E3User interface keyswitch or software mismatch (only appears in diagnostic test…F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure.F:78Console electronics failure.F0 E0No error(s) foundF1 E0EEPROM communications error.F1 E1EEPROM checksum failure.F1 E2UL A/D error(s).F1E1Primary control failure indicating the machine control electronics has failed.F2Touch panel failure.F2 E0Shorted key / Stuck key.F2 E1Keytail unplugged.
View all 55 error codes

Service modes (20)

  • Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the DONE…
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
  • diagnostic["Ensure dryer is in standby mode (plugged in and all indicators off).","Press the following button…
  • Diagnostic Test Mode1
  • Diagnostic: Console switches and indicators["Enter diagnostic test mode.","Press each button or turn the cycle selector to each cycle…
  • Diagnostic: Door Switch["Enter diagnostic test mode.","Open the door
  • Diagnostic: Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
  • Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
  • Last fault code displayPress and hold CANCEL/OFF key for 5 seconds
  • Loads Test Mode["Ensure the dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds…
  • Manual Load Test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Clothes Dry…
  • Self-Diagnostic / Test Mode["Press and hold the CANCEL/OFF button while opening the door.","While still holding the CANCEL/OFF…
  • Self-Diagnostic / Touch Panel and Electronic Control Test["1
  • Self-Diagnostic Test Mode["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the DONE…
  • Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
  • Temperature Adjustment (Calibration)Press and hold BAKE pad for 5 seconds
  • Test mode (diagnostic)Within 60 seconds of power up, simultaneously hold down the BAKE and CLOCK keys for 5 seconds
  • User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
  • User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…

Full entry steps, exit procedures, and test sequences are available in Max.

76,000+ service documents · 19,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax