Model reference
Amana OU-80-A3
Furnace
3 documents55 error codes26 service modes
Available documentation
Installation Guide
- Installation Instructions36 pg
- Installation Instructions8 pg
- Installation Instructions17 pg
MyPros+ Max
Diagnose your Amana OU-80-A3.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (55)
CodeMeaning
1c1cShorted key detected on the membrane keyboard.1c2cMembrane keyboard disconnected from the control board.1c4cBoard-to-board communication failure.1c6cEEPROM hardware fault.1c7cControl not calibrated.1c81EEPROM CRC error in Cook Profile data.1c8cEEPROM CRC error in User Options data.1d11Unlocked runaway oven temperature exceeding 600°F.1d21Locked runaway oven temperature exceeding 950°F.3d11Oven temperature sensor circuit is open.3d21Oven temperature sensor circuit is shorted.3d41Meat probe circuit is shorted.3d51Meat probe not calibrated.4d11Door switch not closed when door is locked.4d21No cooling fan rotation detected.4d31Cooling fan is on when it should be de-energized.4d41Cooling fan overspeed condition detected.4d51Door switch circuit fault.9d11Door latch will not lock.9d21Door latch will not unlock.9d31Door latch reports both locked and unlocked simultaneously.F1-E0EEPROM communication error.F1-E1Upper RTD uncalibrated (internal error).F1-E2Lower RTD uncalibrated (internal error).F1-E5Sensor usage out of range (internal error).F1-E7PCB thermistor/sensor open or shorted.F1-E9WIDE Queue full.F1E1Indicates a CCU (Cycle Control Unit) problem.F2-E0Keypad disconnected.F2-E1Stuck key detected.View all 55 error codes
F2-E2Stuck key detected.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5-E0Door and latch switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F6-E0Lost communications between control boards.F6-E1Over temperature condition during cook mode (runaway temp).F6-E2Over temperature condition during clean mode (runaway temp).F6-E3Over temperature condition in warming drawer (runaway temp).F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F9-E0Product is mis-wired.L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.
Service modes (26)
- Auto Test1
- Clear Fault Codes["Enter Diagnostic Mode by pressing CANCEL > CANCEL > START within 5 seconds.","Press TEMP/TIME '+'…
- Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- Control Reset1
- control_lockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- control_reset1
- Customer-Focused Dryness Level Adjustment1
- Demo Mode1
- Diagnostic Mode1. Plug in oven or connect power. 2. Press CANCEL > CANCEL > START within 5 seconds to enter…
- Display Test1
- display_test1
- Fault Code Viewing and Clearing1
- Faults Access1
- faults_access1
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Quick Test Mode (EOC III)1
- quick_test1
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Service Mode1
- service_mode1
- Software Version Display1
- Software Versions Access1
- software_versions_access1
- Temperature Calibration1
- Test Mode1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands