Model reference

Amana OU-80-A3

Furnace

55 error codes26 service modes
MyPros+ Max

Diagnose your Amana OU-80-A3.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (55)

View all 55 error codes
F2 E2Stuck key detected.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3 E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5-E0Door and latch switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F6 E1Over temperature condition during cook mode (runaway temp).F6 E2Over temperature condition during clean mode (runaway temp).F6 E3Over temperature condition in warming drawer (runaway temp).F6-E0Lost communications between control boards.F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F9-E0Product is mis-wired.L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.

Service modes (26)

  • Auto Test1
  • Clear Fault Codes["Enter Diagnostic Mode by pressing CANCEL > CANCEL > START within 5 seconds.","Press TEMP/TIME '+'…
  • Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
  • Control Reset1
  • control_lockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
  • control_reset1
  • Customer-Focused Dryness Level Adjustment1
  • Demo Mode1
  • Diagnostic Mode1. Plug in oven or connect power. 2. Press CANCEL > CANCEL > START within 5 seconds to enter…
  • Display Test1
  • display_test1
  • Fault Code Viewing and Clearing1
  • Faults Access1
  • faults_access1
  • Install Diagnostics1
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Quick Test Mode (EOC III)1
  • quick_test1
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Service Mode1
  • service_mode1
  • Software Version Display1
  • Software Versions Access1
  • software_versions_access1
  • Temperature Calibration1
  • Test Mode1

Full entry steps, exit procedures, and test sequences are available in Max.

76,000+ service documents · 19,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax