mypros+
Model reference

Amana OU-80-A3

Furnace

3 documents55 error codes26 service modes

Available documentation

Installation Guide

  • Installation Instructions36 pg
    Covers this model
  • Installation Instructions8 pg
    Covers this model
  • Installation Instructions17 pg
    Covers this model
MyPros+ Max

Diagnose your Amana OU-80-A3.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (55)

View all 55 error codes
F2-E2Stuck key detected.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5-E0Door and latch switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F6-E0Lost communications between control boards.F6-E1Over temperature condition during cook mode (runaway temp).F6-E2Over temperature condition during clean mode (runaway temp).F6-E3Over temperature condition in warming drawer (runaway temp).F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F9-E0Product is mis-wired.L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.

Service modes (26)

  • Auto Test1
  • Clear Fault Codes["Enter Diagnostic Mode by pressing CANCEL > CANCEL > START within 5 seconds.","Press TEMP/TIME '+'…
  • Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
  • Control Reset1
  • control_lockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
  • control_reset1
  • Customer-Focused Dryness Level Adjustment1
  • Demo Mode1
  • Diagnostic Mode1. Plug in oven or connect power. 2. Press CANCEL > CANCEL > START within 5 seconds to enter…
  • Display Test1
  • display_test1
  • Fault Code Viewing and Clearing1
  • Faults Access1
  • faults_access1
  • Install Diagnostics1
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Quick Test Mode (EOC III)1
  • quick_test1
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Service Mode1
  • service_mode1
  • Software Version Display1
  • Software Versions Access1
  • software_versions_access1
  • Temperature Calibration1
  • Test Mode1

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass