mypros+
Model reference

Amana SC-125-B3

Furnace

2 documents31 error codes11 service modes

Available documentation

Service Manual

  • Service Manual - 1602346353 pg
    Covers this model

Tech Sheet

  • Tech Sheet whirlpool dryer W10606148 Rev C60 pg
    Covers this model
MyPros+ Max

Diagnose your Amana SC-125-B3.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (31)

CodeMeaning
Err1Checksum failure on power board.Err2Hardware problem on power board.Err3Hardware problem with keyboard.Err4Wrong jumper setting on power board.Err5Shorted keypad detected (also triggered if touch panel pressed for more than 30…Err6Options scrambled on power board.Err7Problem with RTD (Resistance Thermal Device).Err70RTD uncalibrated.Err71RTD shorted.Err72RTD open.Err8Over temperature condition detected.Err9Over temperature condition with current less than 2 amps.F1E1Indicates a CCU (Cycle Control Unit) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; this…F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1No voltage detected at the heater relay; this fault code appears ONLY when in…F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6E1Communication error from UI to CCU; communication between the CCU and UI has…F6E2Communication error from CCU to UI; communication between the CCU and UI has…HOTOver temperature during cook time; magnetron TCO tripped or harness issue from…LLow L2 voltage (less than 50V) detected at the CCU; displayed on models 4000…L2Low L2 voltage (less than 50V) detected at the CCU.
View all 31 error codes

Service modes (11)

  • Convection Temperature Calibration Mode["Door must be closed and unit must be in STANDBY mode.","Press HIDDEN PAD.","Press pads 1, 3, 5…
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
  • Fault Code Display and Clear["Activate Service Diagnostic Mode first.","Press and release the 3rd button to display saved fault…
  • Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
  • Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
  • Service Test Mode["Oven must be in STANDBY mode (press PREHEAT ON/OFF to turn off if needed).","Close the…
  • Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
  • User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
  • User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
  • User Options Mode["STANDBY must be displayed (press PREHEAT ON/OFF if not).","Press HIDDEN PAD.","Press PROGRAM SAVE…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass