Model reference
Amana SL-125-B3
Furnace
4 documents39 error codes28 service modes
Available documentation
Service Manual
- Service Manual - W11096080 - Countertop _ Built-In Microwave oven with True Convection50 pg
Tech Sheet
- Tech Sheet - W11087920 - Rev A60 pg
- Tech Sheet whirlpool dryer W10606148 Rev C60 pg
- Tech Sheet - W10403269 - Rev A52 pg
MyPros+ Max
Diagnose your Amana SL-125-B3.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (39)
CodeMeaning
1c1cShorted key detected on the membrane keyboard.1c2cMembrane keyboard disconnected from the control board.1c4cBoard-to-board communication failure.1c6cEEPROM hardware fault.1c7cControl not calibrated.1c81EEPROM CRC error in Cook Profile data.1c8cEEPROM CRC error in User Options data.1d11Unlocked runaway oven temperature exceeding 600°F.1d21Locked runaway oven temperature exceeding 950°F.3d11Oven temperature sensor circuit is open.3d21Oven temperature sensor circuit is shorted.3d41Meat probe circuit is shorted.3d51Meat probe not calibrated.4d11Door switch not closed when door is locked.4d21No cooling fan rotation detected.4d31Cooling fan is on when it should be de-energized.4d41Cooling fan overspeed condition detected.4d51Door switch circuit fault.9d11Door latch will not lock.9d21Door latch will not unlock.9d31Door latch reports both locked and unlocked simultaneously.F1E1Indicates a Cycle Control Unit (CCU) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.View all 39 error codes
F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F6E1Communication between CCU and UI has not been detected (UI to CCU communication…F6E2Communication between CCU and UI has not been detected (CCU to UI communication…FCE1WiFi Module communications lost.L2Low L2 voltage (less than 50V) detected at installation.PFPower failure occurred while the dryer was running.
Service modes (28)
- Component Activation / Quick Service Cycle (LCD in Door Models)["Enter Service Diagnostic Mode (LCD in Door) first.","From the DIAGNOSTICS HOME screen, scroll…
- Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- Control Reset1
- control_lockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- control_reset1
- Customer-Focused Dryness Level Adjustment1
- Demo Mode1
- Display Test1
- display_test1
- Faults Access1
- faults_access1
- Install Diagnostics1
- Key Activation & Encoder Test (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Quick Test Mode (EOC III)1
- quick_test1
- Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Diagnostic Mode (Console Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (LCD in Door Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Open and close the…
- Service Mode1
- Service Test Mode (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- service_mode1
- Software Version Display1
- Software Version Display (Console Models)["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- Software Versions Access1
- software_versions_access1
- User Interface Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass