Model reference
Amana YY-100-A2
Furnace
5 documents62 error codes26 service modes
Available documentation
Installation Guide
- Installation Instructions32 pg
- Installation Instructions64 pg
- Installation Instructions28 pg
- Installation Instructions58 pg
- Installation Instructions56 pg
MyPros+ Max
Diagnose your Amana YY-100-A2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (62)
CodeMeaning
F0 E0Factory defaultF1Internal board failure (A/D error)F1 E0EEPROM communication error.F1 E1Upper RTD uncalibrated (internal error).F1 E2Lower RTD uncalibrated (internal error).F1 E4Model ID error.F1 E5Sensor usage out of range (internal error).F1 E6Latch signal mismatch error.F1 E7PCB thermistor/sensor open or shorted.F1 E9WIDE queue full.F1-E0EEPROM communication error.F1-E1Upper RTD uncalibrated (internal error).F1-E2Lower RTD uncalibrated (internal error).F1-E5Sensor usage out of range (internal error).F1-E7PCB thermistor/sensor open or shorted.F1-E9WIDE Queue full.F1E0Internal board failure / A/D error.F1E1Internal board failure / A/D error.F1E2Internal board failure / A/D error.F2Shorted keyF2 E0Keypad disconnected.F2 E1Stuck key detected.F2 E2Stuck key detected.F2-E0Keypad disconnected.F2-E1Stuck key detected.F2-E2Stuck key detected.F2E0Shorted key.F3Oven sensor opened, oven sensor shorted, or bake/broil range over temperatureF3 E0Main oven sensor open or shorted (upper oven).F3 E1Main oven sensor open or shorted (lower oven).View all 62 error codes
F3 E2Bake/broil range over temperature.F3 E3Clean range over temperature.F3 E4Oven sensor openedF3 E5Oven sensor shortedF3 E6Warming drawer sensor open.F3 E7Warming drawer sensor shorted.F3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E0Oven sensor opened.F3E1Oven sensor shorted.F3E2Bake/broil range over temperature.F3E3Clean range over temperature.F5Door and switches do not agree (clean mode) or door latch not operating (clean…F5 E0Door and latch switches do not agree during Clean mode.F5 E1Door latch not operating during Clean mode.F5-E0Door and latch switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and switches do not agree (clean mode).F5E1Door latch not operating (clean mode).F5E2Door and switches do not agree (clean mode).F6 E0Lost communications.F6 E1Over temperature during cook mode (runaway temp).F6 E2Over temperature during clean mode (runaway temp).F6 E3Over temperature in warming drawer (runaway temp).F6-E0Lost communications between control boards.F6-E1Over temperature condition during cook mode (runaway temp).F6-E2Over temperature condition during clean mode (runaway temp).F6-E3Over temperature condition in warming drawer (runaway temp).F9Miswired house or miswired rangeF9 E0Product is mis-wired.F9-E0Product is mis-wired.F9E0Miswired house or miswired range.
Service modes (26)
- Auto Test1
- Clear Fault Codes["Enter Diagnostic Mode by pressing CANCEL > CANCEL > START within 5 seconds.","Press TEMP/TIME '+'…
- Control ResetAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Control Reset (Soft Reset)1
- Diagnostic Mode1. Plug in oven or connect power. 2. Press CANCEL > CANCEL > START within 5 seconds to enter…
- Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
- Diagnostics Test ModeWhile in Diagnostics Mode, press specific keypads to test individual control relays
- Display TestAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Fault Code Viewing and Clearing1
- Faults (Error Code Review)1
- Faults (View/Clear Error Codes)1
- Faults DisplayAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Last Error Code RecallPress and hold CANCEL/OFF key for 5 seconds until last error code is displayed.
- Semi Automatic TestAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Semi Automatic Test Mode1
- Temperature Adjustment Mode1
- Temperature Calibration1
- Temperature Calibration AdjustmentPress and hold BAKE pad for 5 seconds
- Test Mode1
- Test Mode (Manual Relay Activation)After entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Usage1
- Usage CheckAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Usage Mode1
- Version1
- Version CheckAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Version Mode1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass