Model reference
Amana YY-120-RA
Furnace
1 document72 error codes16 service modes
Available documentation
Tech Tip
- Instruction Sheet - 397971412 pg
MyPros+ Max
Diagnose your Amana YY-120-RA.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (72)
CodeMeaning
F0 E0Factory defaultF0E0No error(s) foundF1EEPROM Communications error.F1 E0EEPROM communication error.F1 E1EEPROM checksum error.F1 E2Lower RTD uncalibrated (internal error).F1 E4Model ID error.F1 E5Sensor usage out of range (internal error).F1 E6Latch signal mismatch error.F1 E7PCB thermistor/sensor open or shorted.F1 E9WIDE Queue full.F1-E0EEPROM Communications failure.F1-E1Upper RTD uncalibrated (internal error).F1E0Replace oven User InterfaceF1E1Oven Appliance Manager failure (not applicable for lower oven on double oven…F1E4Microwave ACU PCBA failure.F2 E0Keypad disconnected.F2 E1Stuck key detected.F2 E2Stuck key detected.F2-E0Shorted Key detected.F2E0Keypad disconnected.F2E1Stuck key failure.F2E2LED error.F2E3Keypad hardware failure.F3 E0Main oven temperature sensor open or shorted (upper oven).F3 E1Oven sensor shortedF3 E2Bake/broil range over temperature.F3 E3Clean range over temperature.F3 E4Oven sensor openedF3 E5Oven sensor shortedView all 72 error codes
F3 E6Warming drawer sensor open.F3 E7Warming drawer sensor shorted.F3-E1Main oven temperature sensor open or shorted (lower oven).F3E0Refrigerator/Main compartment (Z1) thermistor short or open circuit.F3E1Freezer/Main compartment (Z1) thermistor short or open circuit.F3E2Refrigerator Evaporator thermistor short or open circuit.F3E3Freezer Evaporator thermistor short or open circuit.F3E4Deli compartment (Z2) thermistor short or open circuit.F3E5Crisper (Z3) thermistor short or open circuit.F4E1Cavity temperature sensor failure.F4E4Humidity sensor error.F4E9Smart pop error.F5 E0Door switches do not agree.F5 E1Door latch not operating.F5-E0Door and latch switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5-E2Latch error during clean cycle.F5E1Door latch not operating.F6 E1Over temperature condition during cook mode (runaway temp).F6 E2Over temperature condition during clean mode (runaway temp).F6 E3Over temperature condition in warming drawer (runaway temp).F6-E0Lost communications between control boards.F6E0ACU PCBA communication failure.F6E1Cook oven over temperature.F6E2Clean oven over temperature.F6E3Mini oven/warm drawer over temperature (not for built-in ovens).F6E4User interface / Appliance Manager mismatch.F6E5No cavity size command.F7E1Boiler over temperature.F7E2Boiler NTC out of range.F7E3Improper filter reset.F7E4Conductivity sensor not connected.F8E0Low fan speed underspeedF8E1Low fan speed overspeedF8E2High fan speed underspeedF8E3High fan speed overspeedF8E5Exhaust air temperature sensor failure.F9-E0Product is mis-wired.FDE0Ice maker tray thermistor short or open circuit.FDEAIce Maker Jammed (cannot find Homing or end of harvest location).OPOpen circuit detected on thermistor.SHShort circuit detected on thermistor.
Service modes (16)
- Auto Test1
- Bake Temperature Calibration AdjustmentPress and hold BAKE pad for 5 seconds. Current offset (if any) is shown in 3-digit display; CAL is…
- Clear Fault Codes["Enter Diagnostic Mode by pressing CANCEL > CANCEL > START within 5 seconds.","Press TEMP/TIME '+'…
- Diagnostic Mode1. Plug in oven or connect power. 2. Press CANCEL > CANCEL > START within 5 seconds to enter…
- Diagnostics Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to reach standby (display shows…
- Diagnostics Mode - Extended Mode["Plug in range or connect power.","Set clock.","Press OFF, OFF, START to enter Diagnostics Mode."]
- Fault Code Viewing and Clearing1
- Last Error Code RecallPress and hold CANCEL/OFF key for 5 seconds until last error code is displayed.
- Model ID and Cavity Size Programming["After replacing User Interface, plug in range or reconnect power.","The MODEL SELECT Menu…
- Relay Activation Test["Enter Diagnostics Mode (OFF, OFF, START).","Press RELAY ACTIVATION.","Press desired relay (BAKE…
- Service Diagnostics Mode["Press the pulsing JennAir logo to wake up the UI.","Press the middle zone key.","Press CONNECT…
- Status Screen["Enter Diagnostics Mode (OFF, OFF, START).","Press STATUS SCREEN.","Select sub-menu
- Temperature Adjustment (Calibration)Press and hold BAKE pad for 5 seconds. Current offset (if any) is shown in 3-digit display. CAL is…
- Temperature Calibration1
- Temperature Calibration AdjustmentPress and hold BAKE pad for 5 seconds
- Test Mode1
Full entry steps, exit procedures, and test sequences are available in Max.