Model reference

Amana YY-140-MA

Furnace

2 documents54 error codes27 service modes

Available documentation

Tech Tip

  • Instruction Sheet - 397920812 pg
    Covers this model
  • Instruction Sheet - 397921012 pg
    Covers this model
MyPros+ Max

Diagnose your Amana YY-140-MA.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (54)

CodeMeaning
bFIce bin is full (ice maker self-diagnostic).E1Unable to find the ice dump position (ice maker self-diagnostic).E2Unable to find the end-of-harvest position (ice maker self-diagnostic).E3Unable to find the rest position (ice maker self-diagnostic).E4Multiple failures detected during ice maker self-diagnostic.F0-E0Default F codeF0E0No failure present (displays only if user presses and holds CANCEL/OFF key for…F1E0EEPROM communications failure.F1E1Indicates a CCU (Cycle Control Unit) problem.F1E3Fuel type (gas/electric) select failure.F1E4Microwave ACU PCBA failure.F2 E3Key held down too long, or key is shorted.F2E0Key held down too long or shorted key.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatchF2E6CANCEL key failure.F3 E0Temperature sensor (lower) opened.F3 E1Temperature sensor (lower) shorted.F3 E2Temperature sensor (microwave) opened.F3 E3Temperature sensor (microwave) shorted.F3E0Oven sensor opened.F3E1Outlet thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Outlet thermistor has shorted; temperature above 250°F (<500 ohms).F3E3CLEAN range over temperature condition.F3E5Compressor and outlet thermistors are open; will occur if the P14 connector is…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF3E8Compressor sensor is open; this fault code will stop the dryer.F3E9Compressor sensor has shorted; this fault code will stop the dryer.F4-E0Meat probe shorted.F4E1No voltage detected at the heater relay; appears only in Diagnostic Test Mode.
View all 54 error codes

Service modes (27)

  • 12 hour shut offPress and hold CLOCK key for 5 seconds.
  • Audible signal pitch controlPress and hold DELAY START key for 5 seconds.
  • Bake temperature offset adjustment1
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
  • Damp Dry Test["Begin with an empty dryer and clean lint screen","Set Timer to DAMP DRY","Set Fabric…
  • damp_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to known good power…
  • Default F code display (no-fault check)Press and hold '0' key for 5 seconds
  • Default F code display (no-fault verification)Press and hold '0' key for 5 seconds
  • diagnostic["Set Signal End of Cycle switch to HIGH","Set Timer to TIMED DRY or AUTO MOISTURE SENSING PLUS…
  • diagnostic_test["Begin with a fully assembled dryer connected to a known good power source.","Set Door
  • Diagnostic/Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to enter Standby mode (display shows…
  • Diagnostic/Troubleshooting Mode["Press and hold both temperature '–' and '–' buttons (or [▼] and [▼]) simultaneously for 3…
  • Disable/Enable all tones (except end-of-timer and error tones)Press and hold COOK TIME key for 5 seconds.
  • Disable/Enable cycle and timer-end repeating tonesPress and hold TIMER SET key for 5 seconds.
  • Factory Test["Open the door","Set Signal switch to HIGH","Set Timer to TIMED DRY or AUTO MOISTURE SENSING PLUS…
  • Fahrenheit to Celsius conversionPress the BROIL pad for 5 seconds
  • Install Diagnostics["Activate Service Diagnostic Mode first (see Service Diagnostic Mode entry).","Ensure all of step…
  • Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
  • Recall last failure codePress and hold CANCEL/OFF key for 5 seconds
  • Sabbath Mode checkIf 'SAB' appears in digital display, oven is in Sabbath Mode.
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
  • Service Diagnostics Mode["Press and hold both '—' (minus) temperature buttons simultaneously for 3 seconds (or both [▼] and…
  • Software revision numberPress and hold TIME key for 5 seconds.
  • Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
  • Temperature calibration offsetPress and hold BAKE pad for 5 seconds
  • Temperature unit conversion (Fahrenheit to Celsius)Press the BROIL pad for 5 seconds
  • Verify fuel typePress and hold START/ENTER key for 5 seconds

Full entry steps, exit procedures, and test sequences are available in Max.

76,000+ service documents · 19,000+ error codes · 100+ brands

Get Started