mypros+
Model reference

Amana YY-140-RA

Furnace

6 documents64 error codes25 service modes

Available documentation

Tech Tip

  • Instruction Sheet - 397971512 pg
    Covers this model
  • Instruction Sheet - 85234938 pg
    Covers this model
  • Instruction Sheet - 397920812 pg
    Covers this model
  • Instruction Sheet - 82690922 pg
    Covers this model
  • Instruction Sheet - 854179812 pg
    Covers this model
  • Instruction Sheet - 397921012 pg
    Covers this model
MyPros+ Max

Diagnose your Amana YY-140-RA.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (64)

View all 64 error codes
F3E2Outlet thermistor has shorted; temperature above 250°F (<500 ohms).F3E3CLEAN range over temperature condition.F3E5Compressor and outlet thermistors are open; will occur if the P14 connector is…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF3E8Compressor sensor is open; this fault code will stop the dryer.F3E9Compressor sensor has shorted; this fault code will stop the dryer.F4-E0Meat probe shorted.F4E1No voltage detected at the heater relay; appears only in Diagnostic Test Mode.F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5-E0Lower cavity over temperature while cleaning.F5-E1Door latch not operating.F5E0Door switches do not agree.F5E1Door latch not operating.F5E2Latch error during CLEAN cycle.F6-E0Lower cavity over temperature during cooking.F6-E1Microwave cavity over temperature during cooking.F6E1Communication between the CCU and UI has not been detected (UI to CCU…F6E2Communication between the CCU and UI has not been detected (CCU to UI…F8-E0Self-clean latch will not lock.F8-E1Self-clean latch will not unlock.F8-E2Oven over temperature while door open and latch lock.F8-E3Oven over temperature while door open and latch unlock.F8-E4Oven over temperature while door close and latch unlock.F8E5Exhaust air temperature detection failure.F9E1Drain system errorL2Low L2 voltage (less than 50V) detected at the CCU.LFLint filter has been removed from running position.OPThermistor open circuit detected.PAAll ice maker self-diagnostic test steps passed successfully.PFPower failure occurred while the dryer was running.SABOven is in Sabbath Mode.SHThermistor short circuit detected.

Service modes (25)

  • 12 hour shut offPress and hold CLOCK key for 5 seconds.
  • 12 Hour Shutoff TogglePress and hold CLOCK pad for 5 seconds.
  • Audible signal pitch controlPress and hold DELAY START key for 5 seconds.
  • Bake temperature offset adjustment1
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
  • Default F code display (no-fault check)Press and hold '0' key for 5 seconds
  • Default F code display (no-fault verification)Press and hold '0' key for 5 seconds
  • Diagnostic/Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to enter Standby mode (display shows…
  • Diagnostic/Troubleshooting Mode["Press and hold both temperature '–' and '–' buttons (or [▼] and [▼]) simultaneously for 3…
  • Disable/Enable all tones (except end-of-timer and error tones)Press and hold COOK TIME key for 5 seconds.
  • Disable/Enable cycle and timer-end repeating tonesPress and hold TIMER SET key for 5 seconds.
  • Fahrenheit to Celsius conversionPress the BROIL pad for 5 seconds
  • Fahrenheit to Celsius TogglePress and hold BROIL pad for 5 seconds.
  • Install Diagnostics["Activate Service Diagnostic Mode first (see Service Diagnostic Mode entry).","Ensure all of step…
  • Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
  • Recall last failure codePress and hold CANCEL/OFF key for 5 seconds
  • Sabbath Mode checkIf 'SAB' appears in digital display, oven is in Sabbath Mode.
  • Sabbath Mode ExitSabbath Mode is indicated by "SAB" in the digital display.
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
  • Service Diagnostics Mode["Press and hold both '—' (minus) temperature buttons simultaneously for 3 seconds (or both [▼] and…
  • Software revision numberPress and hold TIME key for 5 seconds.
  • Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
  • Temperature calibration offsetPress and hold BAKE pad for 5 seconds
  • Temperature unit conversion (Fahrenheit to Celsius)Press the BROIL pad for 5 seconds
  • Verify fuel typePress and hold START/ENTER key for 5 seconds

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands