Model reference
Amana YY-100-A3
Furnace
1 document71 error codes26 service modes
Available documentation
Installation Guide
- Installation Instructions20 pg
MyPros+ Max
Diagnose your Amana YY-100-A3.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (71)
CodeMeaning
E0 F1EEPROM communication error.E0 F2Keypad disconnected.E0 F3Main oven temperature sensor open or shorted (upper cavity).E0 F5Door and latch switches do not agree during Clean mode.E0 F6Lost communications.E0 F9Product is mis-wired.E1 F1Upper RTD uncalibrated.E1 F2Stuck key.E1 F3Main oven temperature sensor open or shorted (lower cavity).E1 F5Door latch not operating during Clean mode.E1 F6Over temperature during cook mode (runaway temp).E2 F1Lower RTD uncalibrated.E2 F2Stuck key.E2 F6Over temperature during clean mode (runaway temp).E3 F6Over temperature in warming drawer (runaway temp).E5 F1Sensor usage out of range.E7 F1PCB thermistor/sensor open or shorted.E9 F1WIDE queue full.F1Internal board failure (A/D error)F1 E0EEPROM communication error.F1 E1Upper RTD (resistance temperature detector) uncalibrated.F1 E2Lower RTD uncalibrated.F1 E5Sensor usage out of range.F1 E7PCB thermistor/sensor open or shorted.F1 E9WIDE queue full.F1-E0EEPROM communication error.F1-E1Upper RTD uncalibrated (internal error).F1-E2Lower RTD uncalibrated (internal error).F1-E5Sensor usage out of range (internal error).F1-E7PCB thermistor/sensor open or shorted.View all 71 error codes
F1-E9WIDE Queue full.F1E0Internal board failure / A/D error.F1E1Internal board failure / A/D error.F1E2Internal board failure / A/D error.F2Shorted keyF2 E0Keypad disconnected.F2 E1Stuck key.F2 E2Stuck key.F2-E0Keypad disconnected.F2-E1Stuck key detected.F2-E2Stuck key detected.F2E0Shorted key.F3Oven sensor opened, oven sensor shorted, or bake/broil range over temperatureF3 E0Main oven temperature sensor open or shorted (upper cavity).F3 E1Main oven temperature sensor open or shorted (lower cavity).F3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E0Oven sensor opened.F3E1Oven sensor shorted.F3E2Bake/broil range over temperature.F3E3Clean range over temperature.F5Door and switches do not agree (clean mode) or door latch not operating (clean…F5 E0Door and latch switches do not agree during Clean mode.F5 E1Door latch not operating during Clean mode.F5-E0Door and latch switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and switches do not agree (clean mode).F5E1Door latch not operating (clean mode).F5E2Door and switches do not agree (clean mode).F6 E0Lost communications.F6 E1Over temperature during cook mode (runaway temperature).F6 E2Over temperature during clean mode (runaway temperature).F6 E3Over temperature in warming drawer (runaway temperature).F6-E0Lost communications between control boards.F6-E1Over temperature condition during cook mode (runaway temp).F6-E2Over temperature condition during clean mode (runaway temp).F6-E3Over temperature condition in warming drawer (runaway temp).F9Miswired house or miswired rangeF9 E0Product is mis-wired.F9-E0Product is mis-wired.F9E0Miswired house or miswired range.
Service modes (26)
- Auto Test1
- Clear Fault Codes["Enter Diagnostic Mode by pressing CANCEL > CANCEL > START within 5 seconds.","Press TEMP/TIME '+'…
- Control ResetAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Control Reset (Soft Reset)1
- Diagnostic Mode1. Plug in oven or connect power. 2. Press CANCEL > CANCEL > START within 5 seconds to enter…
- Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
- Diagnostics Mode (includes Semi Automatic Test)["Press CANCEL, then CANCEL, then START within 5 seconds.","If control does not enter Diagnostics…
- Diagnostics Test ModeWhile in Diagnostics Mode, press specific keypads to test individual control relays
- Display TestAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Fault Code Viewing and Clearing1
- Faults (Error Code Review)1
- Faults (view stored fault codes)1
- Faults (View/Clear Error Codes)1
- Faults DisplayAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Semi Automatic TestAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Semi Automatic Test Mode["Enter Diagnostics Mode first (CANCEL>CANCEL>START within 5 seconds).","Press TEMP/TIME '+' or '-'…
- Temperature Adjustment Mode1
- Temperature Calibration1
- Test Mode1
- Test Mode (Manual Relay Activation)After entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Usage1
- Usage CheckAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Usage Mode1
- Version1
- Version CheckAfter entering Diagnostics Mode, press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads…
- Version Mode1
Full entry steps, exit procedures, and test sequences are available in Max.