6 documents80 error codes24 service modes
Available documentation
Tech Sheet
- Kenmore Whirlpool Dryer 110 63932100 Tech Sheet 39795408 pg
- tech-sheet-W10832390-RevC.pdf5 pg
- Kenmore Whirlpool Dryer 110 C64992300 Tech Sheet 854591012 pg
Installation Guide
- Instruction Sheet48 pg
- Installation Instructions7 pg
- Installation Instructions7 pg
MyPros+ Max
Diagnose your Amana YY-120-BH.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (80)
CodeMeaning
bFIce bin is full, detected during door ice maker self-diagnostics.E0Sub-code used with F1 (EEPROM communications), F2 (UL A/D errors), F3 (oven…E1Sub-code used with F1 (EEPROM checksum failure), F2 (shorted keypad/cable…E2Sub-code used with F3 indicating bake range over-temperature.E3Sub-code used with F3 indicating clean range over-temperature.E4Door ice maker experienced multiple failures during self-diagnostics.F0No failure has occurred (displayed when most recent F-code is recalled via user…F0 E0No failure (default).F0-E0No failure present.F1EEPROM communications or EEPROM checksum failure in the electronic oven control.F1 E0Internal error.F1 E1Internal error.F1 E2Internal error.F1 E3Internal error.F1 E4Internal error.F1 E5Internal error.F1 E6Internal error.F1 E7Internal error.F1 E8Internal error.F1 E9Internal error.F1-E0EEPROM communications error.F1-E1UL A/D error(s).F1-E2EEPROM checksum failure.F1-E3Fuel type (gas/electric) select failure.F1E1Indicates a Cycle Control Unit (CCU) problem.F2Shorted keypad or keypad cable unplugged (UL A/D errors).F2 E0Stuck key (shorted key).F2 E1Keypad disconnect or keypad disconnected.F2 E5Cancel key low or open.F2-E0Shorted keypad or keypad cable unplugged.View all 80 error codes
F2-E1Shorted keypad or keypad cable unplugged.F2-E6CANCEL key failure.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3Oven sensor opened, oven sensor shorted, bake range over-temperature, or clean…F3 E0Main oven sensor open (top oven sensor opened).F3 E1Main oven sensor shorted (top oven sensor shorted).F3 E2Meat probe shorted.F3 E3Self-clean over temperature (usually 900°F).F3 E4Bottom oven sensor open (bottom/lower oven sensor open).F3 E5Lower/bottom oven sensor shorted.F3 E6Warming drawer sensor open.F3 E7Warming drawer sensor shorted.F3-E0Oven sensor opened.F3-E1Oven sensor shorted.F3-E2Bake range overtemperature.F3-E3Clean range overtemperature.F3E1Indicates that the outlet thermistor is open (temperature drops below 18°F /…F3E2Indicates that the outlet thermistor has shorted (temperature above 250°F /…F3E5Indicates that both the compressor and outlet thermistors are open; will occur…F3E6Indicates the moisture sensor strip is open; only appears in service diagnostic…F3E7Indicates that the moisture sensor strip has shorted; only appears in service…F3E8Indicates that the compressor sensor is open; this fault code will stop the…F3E9Indicates that the compressor sensor has shorted; this fault code will stop the…F4 E2Over temperature during cook mode (temperature runaway).F4 E3Over temperature during clean mode (temperature runaway).F4 E7Over temperature cavity 2 (temperature runaway error).F4E1Indicates no voltage detected at the heater relay; only appears in Diagnostic…F4E3Indicates low air flow that may affect dryer performance.F4E4Indicates low L2 voltage (less than 50V) detected at the CCU.F5Door and latch switches do not agree, solenoid not operating, latch switch…F5 E0Door latch mismatch (door and latch switches do not agree).F5 E1No operating latch or latch not operating.F5 E2Door switch fault.F5 E4Latch switch fault.F5 E5Self-clean temperature set point not reached within required time range…F5 E7Unlock door error (cannot unlock door).F5-E0Door and latch switches do not agree.F5-E1Solenoid not operating or latch switch failureF5-E2Latch error during CLEAN.F6 E4Lost communication between display board and power board.F6 E5Cancel key error.F6E1Communication error between the UI and CCU has not been detected.F6E2Communication error from CCU to UI has not been detected.F9E1Drain system errorL2Low L2 voltage (less than 50V) detected at the CCU.LFIndicates that the HybridCare lint filter has been removed from running…OPOpen thermistor detected during service test thermistor reading.PAAll steps of door ice maker self-diagnostics successfully passed.PFPower failure has occurred.SHShorted thermistor detected during service test thermistor reading.
Service modes (24)
- 12 hour shut offPress and hold CLOCK key for 5 seconds.
- Audible signal pitch controlPress and hold DELAY START key for 5 seconds.
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Damp Dry Test["Begin with an empty dryer and clean lint screen.","Set Timer to DAMP DRY.","Set Fabric…
- damp_dry_test1
- diagnostic1
- Diagnostic mode["Press the Cancel key to place the range in an idle state.","Press the Cancel and Start keys in…
- diagnostic_test["Begin with a fully assembled dryer connected to a known good power source.","Set Door
- Disable/Enable all tones except end-of-timer and error tonesPress and hold COOK TIME key for 5 seconds.
- Disable/Enable cycle and timer-end repeating tonesPress and hold TIMER SET key for 5 seconds.
- Factory Test["Begin with an empty dryer and clean lint screen.","Door must be open.","Set Signal switch to…
- Fahrenheit to Celsius conversionPress and hold BROIL key for 5 seconds.
- Fuel type displayPress and hold START/ENTER key for 5 seconds
- Install Diagnostics["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- less_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to a known good power…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds, press…
- Oven Temperature Calibration["Touch and hold the BAKE keypad for 4 seconds.","The display will indicate the present oven…
- Recall last failure codePress and hold the CANCEL/OFF key for 5 seconds
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostics Mode["Press and hold both '—' and '—' temperature buttons simultaneously for 3 seconds.","A countdown…
- Software revision numberPress and hold TIME key for 5 seconds.
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- Temperature calibration offsetPress and hold BAKE pad for 5 seconds
- User Interface Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.