Model reference
Amana SL-250-B6
Furnace
4 documents22 error codes9 service modes
Available documentation
Service Manual
- ADC AD-75THS ServiceManual-PH5 PastProduction OPL73 pg
Tech Sheet
- Tech Sheet - W11087920 - Rev A60 pg
- Tech Sheet - W10403269 - Rev A52 pg
Other
- R6.pdf86 pg
MyPros+ Max
Diagnose your Amana SL-250-B6.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (22)
CodeMeaning
dOOrDoor switch circuit is open, either due to keyboard entry made while main door…dSFLFault detected in the microprocessor temperature sensor circuit; buzzer will…F1E1Indicates a CCU (Cycle Control Unit) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; this…F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1No voltage detected at the heater relay; this fault code appears ONLY when in…F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6E1Communication error from UI to CCU; communication between the CCU and UI has…F6E2Communication error from CCU to UI; communication between the CCU and UI has…HotPossible overheating condition detected; the microprocessor controller has…LLow L2 voltage (less than 50V) detected at the CCU; displayed on models 4000…L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.SEFLRotational sensor circuit failure indicating a fault in the basket (tumbler)…Service modes (9)
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Hot condition manual resetAfter temperature drops to 220°F or lower, manually close and then open the program switch (PS) on…
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Phase 5 Coin System DiagnosticsThe Phase 5 coin microprocessor controller automatically monitors all major circuits including…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.