Model reference
Amana CRRL-9TB/P75214-3M
Microwave
2 documents20 error codes10 service modes
Available documentation
Tech Tip
- Instruction Sheet - 39800578 pg
- Instruction Sheet - 397971412 pg
MyPros+ Max
Diagnose your Amana CRRL-9TB/P75214-3M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (20)
CodeMeaning
3 beepsThermistor or wire harness is either shorted or open, detected when Push to…E1Thermistor is open.E2Thermistor has shorted.E3User interface keyswitch or software mismatch between console electronics and…F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F1E1Primary control failure in the machine control electronics.F2E1Stuck button or user interface mismatch; only appears in service diagnostic…F3E1Exhaust thermistor circuit is open.F3E2Exhaust thermistor has shorted.F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.L2Low or no line voltage detected (less than 50V) at installation.PFPower failure occurred while the dryer was running.Service modes (10)
- Customer-Focused Drying Mode Adjustment1. Ensure dryer is in standby mode (plugged in with all indicators off, or only DONE indicator on)…
- Diagnostic Test Mode["Ensure the dryer is in Standby Mode (plugged in and all indicators off).","Press the following…
- diagnostic_test["Door must be open","Set Temperature switch to Air Fluff","Set End of Cycle Signal switch to…
- Dryness Level Adjust (TEST #4a)["Enter the Diagnostic Test Mode (MORE TIME, LESS TIME, MORE TIME, LESS TIME within 5…
- Dryness Level Adjust Mode["Enter the Diagnostic Test Mode (MORE TIME → LESS TIME → MORE TIME → LESS TIME within 5…
- Less Dry Test["Begin with a fully assembled, empty dryer with clean lint screen connected to a known good power…
- less_dry_test["Begin with fully assembled, empty dryer with clean lint screen connected to known good power…
- Manual Load Test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Dry…
- Service Diagnostic Mode1
- User Interface/Control System Test1
Full entry steps, exit procedures, and test sequences are available in Max.