Model reference
Amana RC-7D/P71301-1M
Microwave
4 documents66 error codes20 service modes
Available documentation
Tech Sheet
- Tech Sheet - W11794296 - Rev A2 pg
- techsheet-w10420006-reva_W1042000656 pg
Installation Guide
- Instrucciones de instalacion38 pg
- Installation Instructions7 pg
MyPros+ Max
Diagnose your Amana RC-7D/P71301-1M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (66)
CodeMeaning
AFRestricted/low air flow detected that may affect dryer performance.E0No errors present in the ice maker.E1Ice maker errorE2Ice maker errorE3Ice maker errorE4Ice maker errorE5Ice maker errorF0 E7Control board recognized line voltage below 90 VAC.f1 e1Primary control failure.F1 E4UIC (User Interface Control) fault detected.F1 E7ACU voltage input fault.F1E1Indicates a Cycle Control Unit (CCU) problem.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2 E2Upper dryer keypad is sensed pressed for 60 seconds (stuck key).F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2Keypad/Display disconnected from the control.F2E4HMI 1 (Human Machine Interface 1) fault.f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E0Main oven temperature sensor fault.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms)F3E4Inlet thermistor is shorted; temperature above 760°F (<20 ohms)F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4E1No voltage detected at the heater relayView all 66 error codes
F4E3Restricted air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5 E1Lower dryer door circuit error.F5 E6Upper dryer door circuit error.F5E0Main door switch and latch switch do not agree (mismatch).F5E1Main door latch motor fault.F6 E1Communication failure between ACU and UIC.F6E1Communication between the CCU and UI has not been detected (UI to CCU).F6E2Communication between the CCU and UI has not been detected (CCU to UI).F7 E6Lower dryer motor circuit error.F7 E7Upper dryer motor circuit error.F7 E8Lower dryer motor sense errorF7 E9Upper dryer motor sense errorF7E5Cooling fan error.F7E6Cooling fan blocked.f8 e1No voltage detected at the water valve relay (steam models only, only appears…FBE1Main cavity over temperature condition.FC E1Model/Serial number not programmed into control.FC E2Model/Serial number not matching between ACU and UIC.FC E3Wi-Fi connection fault.FC E4USB stick failure (USB full, not detected, or not accessible).FC E5Software uploaded from USB stick does not match the model number of the machine.FC E6Model setup export failureFC E7Model setup import failureFC E8Wi-Fi module not responding or not connected.FCE1Model/Serial number not programmed into the control.FCE2Model/Serial number do not match.FCE3Wi-Fi radio fault.FEE6Main cavity bake element fault.FEE7Main cavity broil element fault.FEE8Main cavity convection element fault.FP E1Coin 1 circuit errorFP E2Coin 2 circuit errorFP E3Card reader communication error.L2Low L2 voltage (less than 50V) detected at the CCU.pfPower failure occurred while the dryer was running.
Service modes (20)
- Component ActivationFrom Service Diagnostics Diagnostics Home screen, select 'Component Activation'
- Customer-Focused Drying Mode Adjustment1
- Customer-Focused Dryness Level Adjustment1. Turn cycle selector knob to an automatic cycle. 2. From the Automatic Cycle Main Screen, press…
- diagnosticPress DELICATES keypad for one second while in any of the set-up codes 1 through 6 (or while dAS…
- Diagnostic Mode["Enter Setup Mode first.","While in any of the set-up codes 1 through 6 (or while dAS displays if…
- helpPress HEAVY DUTY keypad while in special pricing option step 2.XX (or while dAS displays if…
- Help Mode["Enter Setup Mode first.","While in special pricing option step 2.XX (or while dAS displays if…
- model_serial_number_menuEnter Help Mode first
- Model/Serial Number Menu["Enter Help Mode.","While on the S0 screen, press the HEAVY DUTY key.","Use NORMAL key to advance…
- Quick Diagnostic TestFrom Diagnostics Home screen, select 'Error Diagnostic', then select 'Quick Diagnostic Test'
- Service Diagnostic Mode1. Press any sequence of three keys. 2. Repeat the same three-key sequence two more times within 5…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Diagnostics ModePress SW1 and SW2 simultaneously for 3 seconds
- setupPD Models
- Setup Mode["Stacked PD Models
- UI Component TestFrom Diagnostics Home screen, select 'Component Activation', then select 'UI Component Test'
- USB Menu["Enter Help Mode.","While on the USB screen, press the HEAVY DUTY key.","Use NORMAL key to advance…
- usb_menuEnter Help Mode first
- User Interface/Control System TestAfter activating Service Diagnostic Mode, press and release the 1st button used to activate Service…
- wi-fi_menuFrom the F0 screen in setup mode, press HEAVY DUTY keypad to enter Wi-Fi mode
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass