Tech Sheet
- techsheet-3979719.pdf8 pg
- Tech Sheet - W10251191 - Rev A12 pg
- Tech Sheet - W10156038A16 pg
- Tech Sheet - W10156040A12 pg
- Tech Sheet 8563818 Rev A16 pg
- Wiring Diagram - W10668584 - Rev A8 pg
Service Manual
- Job Aid - 4322536A (G-20)76 pg
- Job Aid - Microwave Ovens44 pg
Tech Tip
- Instruction Sheet - 85281108 pg
MyPros+ Max
Diagnose your Amana RC7A-D/P72651-5M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (55)
CodeMeaning
3 beepsThermistor or wire harness is either shorted or open, detected when Push To…AFRestricted airflow condition exists.E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchF-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-24Inlet thermistor is open (only appears in diagnostic test mode).F-25Inlet thermistor is shorted (only appears in diagnostic test mode).F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-30Restricted airflow condition exists (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.View all 55 error codes
F:72Console electronics failure.F:73Console electronics failure.F:74Console electronics failure.F:75Console electronics failure.F:76Console electronics failure.F:77Console electronics failure.F:78Console electronics failure.F1E1Indicates a Cycle Control Unit (CCU) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface Software Error 1F2E3User Interface Software Error 2F3E1Exhaust thermistor is open; temperature drops below 18°F (> 50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (< 500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (> 245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (< 328 ohms).F3E5Inlet and exhaust thermistor are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted air flow that may affect dryer performance.F4E4Low L2 voltage (less than 30V) detected at the CCU.F6E1Communication error from UI to CCUF6E2Communication error from CCU to UIL2Low or no line voltage detected (less than 50V) at installation.PFPower failure occurred while the dryer was running.
Service modes (25)
- Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
- Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
- customer_focused_drying_mode_adjustment1
- Customer-Focused Drying Mode Adjustment1
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["Ensure dryer is in standby mode (plugged in but not powered up).","Press and hold the Dryness…
- Customer-Focused Dryness Level Adjustment1
- Damp Dry Test["Begin with an empty dryer and clean lint screen.","Set Timer to DAMP DRY.","Set Fabric…
- Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
- Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
- Diagnostic Test Mode1
- diagnostic_test_mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
- display_line_voltageAfter all saved fault codes have been displayed in diagnostic test mode, press the End of Cycle…
- Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
- Electronic Oven Control Test["1. Unplug the oven.","2. Remove the cabinet.","3. Discharge the HV capacitor with a 20,000 ohm…
- Factory Test["Open the dryer door.","Set Fabric Care/Temperature switch to AIR FLUFF.","Set Signal switch to…
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Dry…
- manual_load_test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
- Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Software Version Display1
- UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test