mypros+
Model reference

Amana RL-3/P75589-2M

Microwave

8 documents102 error codes32 service modes

Available documentation

Tech Sheet

  • Tech Sheet - 395766116 pg
    Covers this model
  • Tech Sheet - W10176957 - Rev B16 pg
    Covers this model
  • Tech Sheet W1013349016 pg
    Covers this model
  • tech sheet w11332389 revb2 pg
    Covers this model
  • Tech Sheet 8183018 Rev B16 pg
    Covers this model
  • Technical Service Sheet 8183018 Revision B16 pg
    Covers this model

Other

  • Instruction Sheet - 8533775 - Rev A8 pg
    Covers this model
  • tech-sheet-W10865055-RevA60 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RL-3/P75589-2M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (102)

View all 102 error codes
F1E1Motor relay stuck on, indicates an ACU problem.F1E3Incorrect controller installed (electric models only); ACU and/or UI part…F1E4Microwave (MW) relay failure.F1E5ACU parameter file missing; parameter memory invalid.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F20No water detected entering machine or pressure switch trip not detectedF21Long drainF22Door lock errorF23Heater failureF24Water temperature sensor errorF25Drive motor tachometer errorF26Door switch errorF26EDispenser system errorF27Overflow conditionF28Serial communication error between the CCU and the MCU.F29Door unlock errorF2E1Touch panel failure.F2E4UI software errorF2E5UI software errorf3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F30Dispenser system errorF31Motor Control Unit (MCU) failureF32Pressure switch failureF33Analog pressure sensor failureF34Motor Control Unit failureF35Steamer communication failureF36Steamer electronic board relays errorF37Total steamer failureF38Steamer inlet valve failureF39Steamer time out reachedF3E1Exhaust thermistor is open or shorted; open if temperature drops below 18°F…F3E2Moisture sensor strip is open or shorted; only appears in service diagnostic…F3E3Inlet thermistor is open or shorted; open if temperature drops below 18°F…F40Central Control Unit heartbeat failureF41User Interface heartbeat failureF42Not supportedF43Steamer inlet valve failureF44Steamer time out reachedF45Central Control Unit heartbeat failureF46User Interface heartbeat failureF47Not supportedF48Steamer inlet valve failureF49Steamer time out reachedF4E1Heater 1 failure or connector problem; no voltage detected at the heater relay.F4E2Heater 2 failure or connector problem (electric models only); no voltage…F4E3Exhaust air temperature detection failure.F4E4Low L2 voltage (less than 50V) detected at the ACU (electric models only).F50Central Control Unit heartbeat failureF51User Interface heartbeat failureF53Not supportedF60Central Control Unit heartbeat failureF61User Interface heartbeat failureF64Steamer inlet valve failureF66Steam temperature sensor (NTC) errorF6E2Communication errorF6E3Communication errorF70Not supportedF71User Interface heartbeat failureF74UI EEPROM failuref8 e1No voltage detected at the water valve relay (steam models only, only appears…F99Not supportedF9E3Cavity light / Cooling fan relay failure (only occurs in Diagnostics).FDE2Turntable relay failure (only occurs in Diagnostics).FDE3Exhaust fan relay failure (only occurs in Diagnostics).L2Low L2 voltage (less than 30V) detected at the CCU.pfPower failure occurred while the dryer was running.rLUnload indicationSdSuds lockSudSuds lock

Service modes (32)

  • Automatic Diagnostic Test (Quick Entry)1
  • Customer-Focused Drying Mode Adjustment1
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS or DRY LEVEL…
  • diagnostic1
  • Diagnostic Test["Washer must be empty and control must be in OFF state.","Close the door.","Under Cycles, press…
  • Diagnostic Test (Full - with error history and software versions)Press and hold a button for 2-5 seconds, then release
  • Diagnostic Test (with error history)["Close the door.","Press and hold any one button for 2-5 seconds, then release.","Press and hold…
  • Diagnostic Test Mode["Open the dryer door.","Set Temperature switch to Air Fluff.","Set End of Cycle Signal switch to…
  • Diagnostic Test Only["Execute with an empty drum.","Close the door.","Push power.","Select the Drain and Spin…
  • Diagnostic Test Only (automated test without error history)1
  • Diagnostic Test Only (Quick Start)1
  • Diagnostic Test with Error History and SW Versions["Washer must be empty and control must be in OFF state.","Close the door.","Select any one key…
  • diagnostic_test_only1
  • Display Last Stored Failure Code["Under Cycles, press DRAIN/SPIN.","Press SPIN SPEED and select NO SPIN.","Under Options, press and…
  • Error History, Software Version, and Diagnostic Test["Washer must be empty and control must be in OFF state.","Close the door.","Select any one key…
  • Error History, Software Versions and Diagnostic Test1. Washer must be empty and control must be in OFF state. 2. Close the door. 3. Select any one key…
  • Full Diagnostic (Error History, Software Versions, and Diagnostic Test)["Washer must be empty and control in OFF state.","Close the door.","Select any one key except…
  • Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
  • Less Dry Test["Begin with a fully assembled, empty dryer with clean lint screen connected to a known good power…
  • less_dry_test1. Set configuration
  • Manual Diagnostic Test["Washer must be empty and control in OFF state.","Close the door.","Select any one key except…
  • Monthly Maintenance/Cleaning Cycle["Open washer door and remove all items; close door.","Open dispenser drawer and remove detergent…
  • Quick Diagnostic Test (Automated Test Only)1
  • Quick Diagnostic Test (Automatic Test Only)["Drum must be empty.","Close the door.","Push power.","Select the Drain and Spin…
  • Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE/COMPLETE…
  • Service Mode (Error Code Recall and Diagnostic)1. Select any one key (except PAUSE/CANCEL). 2. Using the same key
  • Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
  • Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
  • Steamer Functionality CheckupClose the door
  • steamer_functionality_checkup1
  • Touch Panel and ACU Test (Diagnostics mode)["Plug in microwave oven or reconnect power.","In idle mode, close the door, turn off hood light…
  • User Interface/Control System TestAfter activating Service Diagnostic Mode, press and release the 1st button used to activate Service…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands