Model reference
Amana RR-4D/P71100-5M
Microwave
5 documents44 error codes17 service modes
Available documentation
Service Manual
- servicemanual w10881701 l 9164 pg
- Job Aid - 4322536A (G-20)76 pg
Tech Sheet
- Tech Sheet - W11087920 - Rev A60 pg
- Tech Sheet - W10403269 - Rev A52 pg
Installation Guide
- Installation Instructions9 pg
MyPros+ Max
Diagnose your Amana RR-4D/P71100-5M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (44)
CodeMeaning
AFRestricted airflow detected that may affect dryer performance.F1Internal circuit board failure or A/D error (LCC 90/95 display)f1 e1Primary control failure.F1E0Internal circuit board failure (LCC 180/190 display).F1E1Primary control failure.F1E2A/D error (LCC 180/190 display).F1E3Incorrect controller installed (electric models only); ACU or UI part number…F1E5ACU parameter file missing; parameter memory invalid.F2Shorted key on the control panel (LCC 90/95 display).f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E0Shorted key on the control panel (LCC 180/190 display).F2E1Stuck button or user interface mismatch (keypad/user interface failure)F2E2User Interface software errorF2E3UI and ACU model ID parameter mismatch caused by replacement of either UI or…F2E4UI software errorF2E5UI software errorF3Oven sensor open circuit (LCC 90/95 display)f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E0Oven temperature sensor open circuit (LCC 180/190 display).F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open (temperature below 18°F / >245k ohms) or shorted…F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedf4 e4Low line voltage detected.View all 44 error codes
F4E1Heater 1 failure or connector problem; no voltage detected at the heater relay.F4E2Heater 2 failure or connector problem (electric models only); no voltage…F4E3Restricted airflow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the ACU (electric models only).F4E5High limit exceeded; temperature threshold of the dryer has been exceeded…F5Door and door position switch mismatch during clean mode (LCC 90/95 display).F5E0Door and door position switch mismatch during clean mode (LCC 180/190 display).F5E2Door and door position switch mismatch during clean mode (LCC 180/190 display).F6E1Communication error from UI to CCUF6E2Communication errorF6E3Communication errorF8E1No voltage detected at the water valve relay (steam models only)L2Low L2 voltage (less than 30V) detected at the CCU.pfPower failure occurred while the dryer was running.
Service modes (17)
- Adjusting Customer-Focused Dryness Level["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRY LEVEL button for…
- diagnosticPress CANCEL > CANCEL > START within 5 seconds. Display shows 'tSt' (LCC 90/95) or 'tESt' (LCC…
- diagnostic_test (relay test)While in diagnostic mode, press the following buttons to test individual relays
- Fault Code Display / Clear["1. Activate Service Diagnostic Mode first.","2. Press and release the 3rd button used to activate…
- Install Diagnostics1
- Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
- User Interface Test1
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass