Error codes (52)
CodeMeaning
E1Temperature sensing circuit is open.E2Temperature sensing circuit is shorted.E3Blower rotational speed dropped below 500 RPMs during a cycle; all outputs…E4Tumbler rotational speed dropped to 0 during a cycle; all outputs turned off.E5Dry rack sensor signal lost during a Dry Rack cycle; all outputs turned off.E6Exhaust temperature exceeded 87.7°C (190°F); all outputs turned off.F01Oven temperature sensor opened.F02Welded element relays.F03Appliance Manager EEPROM error.F04Appliance ManagerF05Door or Latch Problems.F06Appliance Manager Malfunction.F07Encoder Failure.F08Cancel Button Disconnected.F1E1Indicates a CCU (Cycle Control Unit) problem.F1E2MCU errorF20Water Temperature Out of Range.F21Water Level Sensor Error.F23Boil Over Temperature.F24Drain Button Disconnected.F25Boiler Failure.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; this…F2E2User Interface software errorF2E3Unsupported cycleF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the…View all 52 error codes
F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E0Heater is not detectedF4E1No voltage detected at the heater relay; this fault code appears ONLY when in…F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5E1Door switch errorF5E2Door lock errorF5E3Door unlock errorF6E1Communication error from UI to CCU; communication between the CCU and UI has…F6E2Communication error from CCU to UI; communication between the CCU and UI has…F6E3Communication error CCU to UIF7E1Drive motor speed sensing error / washer overloadF7E2MCU overheat and/or motor overheatF8E0Steam inlet valve errorF8E1No water detected entering washer or pressure sensor trip not detectedF8E3Overflow conditionF9E1Long drainL2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.rLLoad detected during the washer cleaning cycle (remove load); saved as F0E1.SdSuds detected (alternate display)SudSuds detected
Service modes (19)
- Auto Boiler Test (Select Steam position)["1
- Boil Dry Test["1. Drain the reservoir completely. Do not stop draining operation until no water exits from the…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Diagnostic Test #1 - Controls Operation["Ensure dryer is in Standby Mode (plugged in, all indicators off).","Within 5 seconds, press
- Diagnostic Test #2 - Machine Operation["Ensure dryer is in Standby Mode (plugged in, all indicators off).","Within 3 seconds, press
- Fault Code Display and Clear["Activate Service Diagnostic Mode first.","Press and release the 3rd button to display saved fault…
- Fault/Error Code Display["Activate Service Diagnostic Mode first.","Press and release the 3rd button used to activate…
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Menu Mode (Gas/Electric Configuration)["Ensure dryer is in Standby mode (plugged in, all indicators off).","Within 3 seconds, press
- Quick Diagnostic Test["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Service Test / Component Test["1
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- Steam Failure Reset["1
- Test #5a - User Interface Keypad Test["Unplug dryer or disconnect power.","Press and hold Start and Cycle End Tone buttons.","While…
- Test #5a - User Interface Keypad Test Mode["Unplug dryer or disconnect power.","Press and hold Start and Cycle End Tone buttons.","While…
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…