mypros+
Model reference

Amana RR-7D

Microwave

5 documents39 error codes13 service modes

Available documentation

Service Manual

  • Technical Manual - W11744594 - Rev D - Whirlpool 27" Front Load Washer90 pg
    Covers this model

Tech Sheet

  • Tech Sheet - W11087920 - Rev A60 pg
    Covers this model
  • Tech Sheet - W10403269 - Rev A52 pg
    Covers this model

Installation Guide

  • Installation Instructions6 pg
    Covers this model
  • Installation Instructions32 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RR-7D.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (39)

CodeMeaning
F0E1Load detected during Clean Washer cycleF0E2OversudsF0E3OverloadF0E4Spin speed limited by water temperature.F0E5Off balance load detectedF1E1Indicates a Cycle Control Unit (CCU) problem.F1E2Fault of the motor control section of the ACU.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E2Main heater stuck onF4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F5E1Door switch faultF5E2Door lock will not lock or door lock failureF5E3Door unlock failureF5E4Door not opened between cyclesF6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F6E3No communication between ACU and DMS.F7E2Motor control internal faultF7E8Motor control over-temperature detected.F7E9Motor locked rotor.
View all 39 error codes

Service modes (13)

  • Component Activation["Enter Service Diagnostic Mode.","Navigate to Service Diagnostic.","Select Component…
  • Customer-Focused Dryness Level Adjustment1
  • Diagnostics Cycle["Enter Service Diagnostic Mode.","Navigate to Service Diagnostic.","Select Diagnostics…
  • Factory Calibration Cycle["Enter Service Diagnostic Mode.","Navigate to Factory Diagnostics.","Select Factory Calibration…
  • Factory Reset["Enter Service Diagnostic Mode.","Navigate to Factory Diagnostics.","Select Factory Reset."]
  • HMI Test["Enter Service Diagnostic Mode.","Navigate to Service Diagnostic.","Select HMI Test.","Sub-tests…
  • Install Diagnostics1
  • Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
  • Sensor Feedback["Enter Service Diagnostic Mode.","Navigate to Service Diagnostic.","Select Sensor Feedback."]
  • Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Software Version Display1
  • User Interface Test1
  • User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass