Model reference
Amana RR7/P72582-1M
Microwave
4 documents47 error codes22 service modes
Available documentation
Tech Sheet
- TechSheet W10918575 RevB32 pg
Tech Tip
- Instruction Sheet - 397972312 pg
- Instruction Sheet - 3978720 - Rev A12 pg
- Instruction Sheet2 pg
MyPros+ Max
Diagnose your Amana RR7/P72582-1M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (47)
CodeMeaning
AFLow inlet air flow detected at install.d13Coin 2 errord16Generation 2 debit card reader errord5Coin 1 errord9Low voltage detection errorF:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30 V) detected (appears ONLY in Diagnostic…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).F01CCU errorF04Accelerometer failureF11Motor Control Unit (MCU) has a failure, possibly a repeating under or…View all 47 error codes
F20No water detected entering washerF21Long drainF22Door lock errorF24Temperature sensor errorF25Tachometer errorF26Door switch errorF27Overflow conditionF28Communication failure between CCU and MCU.F29Door unlock errorF31Overheating of motorF33Pump disconnectedF34Load detected in washer during Washer Cleanout Cycle.F70Communication failure between CCU and UI (User Interface).F73UI failureF74UI failureL2Low line voltage (less than 30 V) detected at installation.PFPower failure occurred while the dryer was running.
Service modes (22)
- Code Display Mode["This mode can be accessed only when the washer is in error state.","Open the service door.","The…
- Code Display Sub-Mode["Open the service door when the washer is in an error state.","The current F code or d code will…
- Customer-Focused Drying Mode Adjustment["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
- Cycle Credit["Enter Flashing Mode (entire display flashing).","Press the HOT button (CC will display)."]
- diagnostic["Set Fabric Care / Temperature switch to AIR FLUFF / NO HEAT","Set Signal switch to LOUDER","Set…
- diagnostic_test["Ensure door is open.","Set Fabric Care / Temperature switch to AIR FLUFF / NO HEAT.","Set Signal…
- Flashing Mode (Diagnostic Sub-Mode)["Open the service door.","Press and hold the COLD button until display segments are…
- Help Mode["Enter set-up mode.","Press the WARM button until set-up code 2.XX is on display.","Press the HOT…
- Help Mode (via dAS mode)["Enter set-up mode.","The message dAS will appear in the display.","Press the HOT button.","Press…
- Help Mode (via Manual Communication)["Enter set-up mode.","Press the WARM button until the set-up code 2.XX is on display.","Press the…
- less_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to known good power…
- Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
- Manual Overview Test["Enter Flashing Mode (entire display flashing).","Press the COTTON/WHITES button."]
- Quick Overview Test["Enter Flashing Mode (entire display flashing).","Press the WARM button."]
- Quick Spin Cycle["Enter Flashing Mode (entire display flashing).","Press the PERM PRESS button."]
- Service Access Code (alternate setup entry without removing console)["If the washer is not in failure mode, open the door.","Press the upper left button.","Press the…
- Service Access Code (No Console Removal)["Press the upper left button.","Press the lower right button.","Press the upper right…
- Service Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
- Setup Mode["Insert access door key, turn, and lift to remove access door.","Alternatively, if a debit card…
- Washer Cleanout Cycle["Enter Flashing Mode (entire display flashing).","Press the COLORS/DELICATES button."]
- Washer Diagnostic Mode["First enter 'Start Operating Set-Up' (setup mode).","Press and hold the COLD button for 2 seconds…
- Washer Diagnostic Mode (Flashing Mode)["Enter Setup Mode (open service access door or insert set-up card).","Press and hold the COLD…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass