Model reference
Amana RRL-8TD/P75593-3M
Microwave
4 documents19 error codes12 service modes
Available documentation
Service Manual
- Service Manual - R021001138 pg
- Service Manual - R023201660 pg
- Service Manual - R023215446 pg
Installation Guide
- Instruction Sheet4 pg
MyPros+ Max
Diagnose your Amana RRL-8TD/P75593-3M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (19)
CodeMeaning
E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchF1E1Indicates a CCU (Cycle Control Unit) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.Service modes (12)
- Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
- Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
- Customer-Focused Dryness Level Adjustment1
- Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
- Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
- Diagnostic Test Mode["Ensure the dryer is in standby mode (plugged in and all indicators off).","Within 5 seconds…
- Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Software Version Display1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax