Model reference
Amana RRL-9TA/P75213-1M
Microwave
6 documents34 error codes12 service modes
Available documentation
Tech Sheet
- FICHE TECHNIQUE - 8304553 - Rev B16 pg
- Tech Sheet - W10156041A16 pg
- Tech Sheet 8543719 110 2506650016 pg
Service Manual
- Instruction Sheet - 854371916 pg
Installation Guide
- Installation Instructions7 pg
- Installation Instructions7 pg
MyPros+ Max
Diagnose your Amana RRL-9TA/P75213-1M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (34)
CodeMeaning
CAAverage current limit trip; a 2-second average current draw greater than 5.55…CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…ErProcessor reset error; the control failed to save cycle information during a…F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F0E0No fault detected (GOOD)F3E1Lower oven sensor shorted or open.F3E3Meat probe shorted.F4E1Convection thermistor fault (microwave oven sensor).F4E2Internal temperature sensor fault (microwave oven sensor).F4E4Humidity sensor fault (microwave oven sensor).F5E0Door and latch switch do not agree.F5E1Door latch not operating.F6E0Lost communications between user interface and appliance manager.F6E3Mini oven/warm drawer over temperature (function not present on this oven).F6E4User interface / appliance manager mismatch.F6E5No cavity size command programmed.F7E0Water level is not high enough or water did not boil fast enough.F7E4Conductivity sensor not connected.L2Low or no line voltage detected (less than 50V) at installation.LdLong drain; it takes longer than 5 minutes to pump out water to the point where…LFLong fill; the water fill time exceeded 10 minutes, causing the water valves to…LSLid switch error; the control cannot detect lid switch opening/closing…View all 34 error codes
obOff balance; the motor controller detected an unrecoverable off-balance…PFPower failure detected during a running cycle; the washer lost power mid-cycle.SLSuds lock; excessive suds detected and the unit was unable to clean out suds…SrStuck relay; the relay has failed in the closed position so the machine…
Service modes (12)
- Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
- Customer-Focused Drying Mode Adjustment1
- Diagnostic modePress OFF, OFF, START to enter diagnostic mode and check fault codes.
- Diagnostic Test Mode1
- Extended diagnostic mode (relay activation and testing)1
- Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Manual Load Test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Dry…
- Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
- Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
- User interface programming (after UI replacement)1
- Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass