mypros+
Model reference

Amana RS-7/P75589-3M

Microwave

5 documents47 error codes27 service modes

Available documentation

Tech Sheet

  • techsheet-w10420006-reva_W1042000656 pg
    Covers this model
  • Tech Sheet - W10393006 - Rev B52 pg
    Covers this model
  • Service Guide - Tech Sheet W1117522244 pg
    Covers this model

Other

  • tech manual w11467698 reva29 pg
    Covers this model
  • tech-sheet-W10865055-RevA60 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RS-7/P75589-3M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (47)

CodeMeaning
AFRestricted/low air flow detected that may affect dryer performance.f1 e1Primary control failure.F1 E4UIC (User Interface Control) fault detected.F1 E7Voltage input fault detected.F1E1Indicates a Cycle Control Unit (CCU) problem.F1E3Incorrect controller installed (electric models only); ACU and/or UI part…F1E5ACU parameter file missing; parameter memory invalid.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface Software ErrorF2E4UI software errorF2E5UI software errorf3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms)F3E4Inlet thermistor is shorted; temperature above 760°F (<20 ohms)F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4E1No voltage detected at the heater relayF4E2Heater 2 failure or connector problem (electric models only); no voltage…F4E3Restricted air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5 E1Dryer door circuit error.F6 E1Communication failure between ACU and UIC.F6E1Communication between the CCU and UI has not been detected (UI to CCU).
View all 47 error codes

Service modes (27)

  • Component ActivationFrom Service Diagnostics Diagnostics Home screen, select 'Component Activation'
  • Customer-Focused Drying Mode Adjustment1
  • Customer-Focused Dryness Level Adjustment1. Turn cycle selector knob to an automatic cycle. 2. From the Automatic Cycle Main Screen, press…
  • diagnosticPress DELICATES keypad for one second while in any of the set-up codes 1 through 6 (or while dAS…
  • Diagnostic Cycle (Factory)["Enter Service Mode.","Navigate to Factory Diagnostics.","Select Diagnostic Cycle.","Press the…
  • Diagnostic Cycle (Service)["Enter Service Mode.","Navigate to Service Diagnostics.","Select Diagnostic Cycle.","Press the…
  • Fault Code Display and Clear["Activate Service Diagnostic Mode first.","Press and release the 3rd button to display the most…
  • Fault/Error Code Display["From the DIAGNOSTICS HOME screen, press ERROR DIAGNOSTIC button."]
  • Fault/Error Code Display and Clear1. Activate Service Diagnostic Mode. 2. Press and release the 3rd button to display next error…
  • helpPress HEAVY DUTY keypad while in special pricing option step 2.XX (or while dAS displays if…
  • Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
  • Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
  • Loads Test Mode["Ensure the dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds…
  • model_serial_number_menuEnter Help Mode first
  • Quick Diagnostic TestFrom Diagnostics Home screen, select 'Error Diagnostic', then select 'Quick Diagnostic Test'
  • Reset Modifiers and Options to Factory Default1
  • Service Diagnostic Mode["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
  • Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Service Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
  • Service Test Mode["Activate Service Diagnostic Mode first.","From the Diagnostics Home screen, scroll down and…
  • setupPD Models
  • Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
  • UI Component TestFrom Diagnostics Home screen, select 'Component Activation', then select 'UI Component Test'
  • usb_menuEnter Help Mode first
  • User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
  • User Interface/Control System Test1
  • wi-fi_menuFrom the F0 screen in setup mode, press HEAVY DUTY keypad to enter Wi-Fi mode

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass