Model reference
Amana RRL-9TB/P75214-2M
Microwave
5 documents21 error codes16 service modes
Available documentation
Service Manual
- Service Manual - R021001138 pg
- Service Manual - R023201660 pg
- Service Manual - R023215446 pg
Tech Tip
- Instruction Sheet W11420067 - Rev A1 pg
- Instruction Sheet - 85281108 pg
MyPros+ Max
Diagnose your Amana RRL-9TB/P75214-2M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (21)
CodeMeaning
E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchF1E1Indicates a Cycle Control Unit (CCU) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface Software Error 1F2E3User Interface Software Error 2F3E1Exhaust thermistor is open; temperature drops below 18°F (> 50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (< 500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (> 245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (< 328 ohms).F3E5Inlet and exhaust thermistor are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted air flow that may affect dryer performance.F4E4Low L2 voltage (less than 30V) detected at the CCU.F6E1Communication error from UI to CCUF6E2Communication error from CCU to UIL2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.Service modes (16)
- Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
- Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
- Customer-Focused Dryness Level Adjustment1
- Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
- Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
- Diagnostic Test Mode["Ensure the dryer is in standby mode (plugged in and all indicators off).","Within 5 seconds…
- Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
- Factory Test["Ensure door is open.","Set Signal switch to HIGH.","Set Timer to TIMED DRY or AUTO MOISTURE…
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Software Version Display1
- UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
Full entry steps, exit procedures, and test sequences are available in Max.