mypros+
Model reference

Amana RV-10/P75085-2M

Microwave

6 documents48 error codes21 service modes

Available documentation

Tech Sheet

  • Tech Sheet20 pg
    Covers this model
  • Tech Sheet - W11087920 - Rev A60 pg
    Covers this model
  • Tech Sheet whirlpool dryer W10606148 Rev C60 pg
    Covers this model
  • tech sheet w11421232 reva60 pg
    Covers this model
  • Tech Sheet - W10403269 - Rev A52 pg
    Covers this model

Service Manual

  • servicemanual w10881701 l 9164 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RV-10/P75085-2M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (48)

CodeMeaning
AFRestricted airflow detected that may affect dryer performance.d1Dryer door sense error on control board or due to power line interference…d12Motor sense error on control board or due to power line interference; cycles…d13Blocked coin 2 or coin drop control circuit failure; coin recognition and price…d16Not receiving communications from installed debit card reader in Enhanced…d4Dryer motor control circuit error; cycles and customer display disabled until…d5Blocked coin 1 or coin drop control circuit failure; coin recognition and…d9Voltage detected below 90 VAC for 8 seconds.f1 e1Primary control failure.F1E1Primary control failure.F1E3Incorrect controller installed (electric models only); ACU or UI part number…F1E4Microwave ACU PCBA failure.F1E5ACU parameter file missing; parameter memory invalid.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Stuck button or user interface mismatch (keypad/user interface failure)F2E2User Interface software errorF2E3UI and ACU model ID parameter mismatch caused by replacement of either UI or…F2E4UI software errorF2E5UI software errorf3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open (temperature below 18°F / >245k ohms) or shorted…F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Compressor and outlet thermistors are open; will occur if the P14 connector is…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shorted
View all 48 error codes

Service modes (21)

  • Adjusting Customer-Focused Dryness Level["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
  • Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRY LEVEL button for…
  • diagnostic["Enter set-up mode (PD models
  • Diagnostics / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to enter Standby mode (colon ':'…
  • Fault Code Display / Clear["1. Activate Service Diagnostic Mode first.","2. Press and release the 3rd button used to activate…
  • Fault Code Display and ClearingFrom Service Diagnostic Mode, press and release the 3rd button to advance through saved fault codes
  • help["Enter set-up mode.","Navigate to special pricing option step 2.XX (or while 'dAS' displays if…
  • Install Diagnostics["Activate Service Diagnostic Mode first (see Service Diagnostic Mode entry).","Ensure all of step…
  • Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
  • Key Activation and Encoder TestFrom Service Diagnostic Mode, press and release the 1st button used to activate Service Diagnostic…
  • Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
  • Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
  • Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
  • set-up["PD Models
  • Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
  • UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
  • User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
  • User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass