Service Manual
- Service Manual Split System Air Conditioner Model: DSB-F244PH57 pg
- Service Manual Split System Air Conditioner Model: DSB-183LH55 pg
- Service Manual Split System Air Conditioner Model: DSB-F244LH54 pg
- Service Manual Split System Air Conditioner Model: DSB-183PH60 pg
- Service Manual Split System Air Conditioner Model: DSB-F183L59 pg
- Service Manual Split System Air Conditioner Model: DSB-240PH-R57 pg
- Service Manual Split System Air Conditioner Model: DSB-F240L-R53 pg
- Service Manual Split System Air Conditioner Model: DSB-240AH-R51 pg
MyPros+ Max
Diagnose your Daewoo IC-9430DWKF7A.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (13)
CodeMeaning
0 blinks (continuous ON blink)Room sensor open or short1 blinkIndoor coil sensor open or short, OR outdoor coil sensor open or short, OR…2 blinkCompressor or electrical parts of compressor error, OR gas leak.2 blinksGas leak detectedContinuous blinkGas leak detectedcontinuous ON blinkRoom sensor open or shortE1Room sensor open or short circuit detected (ON lamp blinks continuously for 8…E2Indoor coil sensor or outdoor coil sensor open or short circuit (ON lamp does…E3Compressor or electrical parts of compressor errorE4Gas leak detectedLED 1 time blinkGas leak detected; unit continuously working.LED 3 times blinkCompressor or electrical parts of compressor error; unit continuously works to…LED 8s blinkRoom sensor open or short circuit, indoor coil sensor open or short, or outdoor…Service modes (7)
- Emergency OperationPress the Emergency/Remote switch on the indoor unit (switch position set to 'Emergency' / GND)
- Remote Controller Functional Test["Power supply the remote controller.","Verify display turns on at beginning.","If display does not…
- Self-Diagnostic["The control automatically performs diagnostic tests to verify system integrity.","Error codes are…
- Self-Diagnostic FunctionThe control automatically runs diagnostic tests to verify system integrity
- Test OperatingDuring the time of test operating, Fan (Indoor, Outdoor) and Compressor run regardless of room…
- Test Operating Mode["During test operating, Fan (Indoor, Outdoor) and Compressor run regardless of room temperature."]
- Test OperationDuring test operating mode, Fan (Indoor, Outdoor) and Compressor run regardless of room temperature.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Daewoo air conditioner models
78,000+ service manuals · 160,000+ error codes · 55+ brands