mypros+
Model reference

Electrolux Zanussi TC2

Dryer

1 document104 error codes7 service modes

Available documentation

Service Manual

  • SERVICE MANUAL DRYERS - Condenser dryer with electronic control system57 pg
    Covers this model
MyPros+ Max

Diagnose your Electrolux Zanussi TC2.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (104)

View all 104 error codes
E5CInput voltage is too high.E5dData transfer error between inverter and main PCB.E5ECommunication error between inverter and main PCB.E5FInverter is drawing too much current (>4.5 A).E5HInverter PCB fails to start the motor.E61Insufficient heating (maximum time exceeded).E62Power relay to heater unit faulty.E63Intervention of auto-reset thermostat on the heater unit.E64Heater thermostat fault.E65Fan motor triac faulty.E66Fan motor thermal protection activated.E67Triac control faulty (fan motor).E68Current leak to the ground.E69Insufficient heating during the washing phase.E6AHeating relay sensing faulty.E6HHeating element power relay faulty (inconsistency between sensing and relay…E71NTC1 sensor faulty.E72NTC2 sensor faulty.E73Fault in NTC sensor on drying duct (voltage out of range, short-circuit or open…E74NTC probe for wash cycle improperly positioned.E82Selector in OFF position faulty.E83Selector positions wrong.E86Selector configuration error.E87Display board microprocessor faulty.E91Communication error between main PCB and display board.E92Communication inconsistency between main PCB and display board (incompatible…E93Error in the configuration of the appliance (EEPROM configuration incorrect).E94Error in the configuration of the drying cycle (EEPROM configuration incorrect).E95Communication error between micro-processor and EEPROM.E97Incongruence between selector and cycles (configuration error).E98Display board configuration error.E9bCommunication error between micro-processor and FLASH memory.E9CDisplay board touch sensor faulty.E9dClock faulty.E9EAppliance configuration error.E9FCommunication error between main PCB and inverter board.E9HCommunication error between micro-processor and FLASH memory.EA1CRM board communication faulty.EA2CRM board protocol inconsistent.EA3Board selector faulty.EA4Selector protocol wrong.EA6No signal from the DSP during motor activation.EB1Power frequency to appliance out of limits.EB2Power voltage too high.EB3Power voltage too low.EC1Voltage incongruence between boards.EC2Frequency incongruence between boards.EC3CRM resistance out of time (only in diagnostic mode).EC4Steam generator (CRM) heater relay fault.EC5CRM thermostat faulty.EC6CRM piloting faulty.EC7CRM pump triac fault.EC8CRM pump diode short-circuited.EC9CRM pump piloting faulty.ECAWater tank empty.Ed1Data transfer error between WD PCB and main PCB.Ed2Drying heating element relay 1 faulty.Ed3Drying heating element relay 2 faulty.Ed4Relay which switches the power between the washing and drying heating element…Ed6No communication between main PCB and display board (INPUT).Ed7No communication between main PCB and remote display board.EF0Excessive detergent / Water leakage (Aqua Control System).EF1Drain filter clogged (drain phase too long).EF2Overdosing of detergent (too much foam during drain phases).EF3Aqua control system intervention.EF4Water fill pressure too low, no signal from flowmeter and electronically…EF5Unbalanced loadEF6Electronically controlled valve blocked with operating flowmeter.EH0Voltage or frequency outside normal values.EH1Appliance power supply frequency out of limits.EH2Supply voltage too high.EH3Supply voltage too low.EHEIncongruence between safety relay (in the main PCB) and safety sensing circuit.EHFSafety sensing circuit faulty (wrong input voltage to micro-processor).

Service modes (7)

  • alarm_deletion1
  • Conductivity adjustment mode["1. Turn the programme selector to switch on the appliance.","2. In selection mode (set-up)…
  • demo1
  • diagnostic1
  • Diagnostic mode["1. Ensure the appliance is switched OFF (selector at position 0).","2. Switch the appliance ON by…
  • operating_time_counter1
  • rapid_alarm_readingTouch the START/PAUSE sensor and the nearest option sensor simultaneously and hold for at least 2…

Full entry steps, exit procedures, and test sequences are available in Max.

Related Electrolux Zanussi dryer models

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started