Model reference
Electrolux Zanussi TC6
Dryer
1 document107 error codes10 service modes
Available documentation
Service Manual
- SERVICE MANUAL DRYERS - Condenser dryer with electronic control system57 pg
MyPros+ Max
Diagnose your Electrolux Zanussi TC6.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (107)
CodeMeaning
E00No alarm.E10No water fillingE11No water fillingE13Not enough waterE20No drainingE21Canister fill pump triac faulty.E22Triac sensing circuit for the canister fill pump faulty.E23Incongruence between drainpump and electronicE24Drain pump triac sensing failureE30Pressure sensor defectE31Conductimetric sensor signal frequency too high.E32Conductimetric sensor signal frequency too low.E33Displayed in the last alarm if diagnostics position 8 is NOT OK (conductimetric…E34Incongruence between pressure sensor and antiboil level 2 (fault for time…E35Safety level (pressure sensor)E36Antiboil 1 sensing failureE37No pressure differences detectedE38Pressure switch Niv.1 sensing failureE39Sensing failureE3AHeating element relay defect.E40Lid openE41Door is unlocked during the cycle (timeout 15 sec).E42Door lock defectE43Door lock triac defect.E44Door lock sensing failureE45Door closure sensor fault.E50Motor triac short circuit.E51Motor power triac short-circuited.E52Intervention of motor overheating safety cut-out.E53Motor triac sensing circuit faulty.View all 107 error codes
E54Motor inoperational.E55No signal from tachogenerator, no signal after 15 min.E56Motor triac sensing failureE57Inverter current goes above threshold (>15A).E58Motor phase current goes above threshold (>4.5A).E59No tacho signal for 3 seconds after new speed target different from zero.E5AHeat sink temperature goes above threshold (88°C).E5BDC bus voltage goes below threshold (<175V).E5CDC bus voltage goes above threshold (>430V).E5DFCV cannot receive and/or transmit a message for more than 2 seconds.E5ECommunication problems between FCV control board and mainboard.E5FFCV control board is continuously asking for configuration parameters due to…E60Insufficient heatingE61Insufficient heating (maximum time exceeded).E62Power relay to heater unit faulty.E63Intervention of auto-reset thermostat on the heater unit.E64Heater thermostat fault.E65Fan motor triac faulty.E66Fan motor thermal protection activated.E67Triac control faulty (fan motor).E68Leakage current in the appliance too high (insulation resistance < 168 kOhm).E70NTC defectiveE71NTC1 sensor faulty.E72NTC2 sensor faulty.E74NTC is not in the correct position in the tub.E80Wrong selector reset position detection.E82Selector in OFF position faulty.E83Selector positions wrong.E84Recirculation pump sensing failureE85Recirculation pump defect.E90Interrupted communication between In/Output electronic and main electronic.E91Interrupted communication between In/Output electronic and main electronic.E92Incongruence between In/Output electronic and electronicE93Error in the configuration of the appliance (EEPROM configuration incorrect).E94Error in the configuration of the drying cycle (EEPROM configuration incorrect).E95Communication error between microprocessor and EEPROM.E96Incongruence between hardware version and cycles configuration.E97Incongruence between selector and cycles (configuration error).E98Incongruence between motor control board and electronic.E99Connection between loudspeaker and In/Output electronic defective.E9AFirmware between loudspeaker and In/Output electronic not ok.EA0DSP defectEA1CRM board communication faulty.EA2CRM board protocol inconsistent.EA3Board selector faulty.EA4Selector protocol wrong.EA5Triac for DPS defect.EA6Drum has blocked in the first approx. 3 or 30 secondsEB0Power supply frequency out of limits.EB1Power frequency to appliance out of limits.EB2Power voltage too high.EB3Power voltage too low.EBELine Safe relay faulty.EBFLine Safe sensing faulty.EC0Inlet valve blocked.EC1Voltage incongruence between boards.EC2Frequency incongruence between boards.EC3CRM resistance out of time (only in diagnostic mode).EC4Steam generator (CRM) heater relay fault.EC5CRM thermostat faulty.EC6CRM piloting faulty.EC7CRM pump triac fault.EC8CRM pump diode short-circuited.EC9CRM pump piloting faulty.ECAWater tank empty.EF0Filter dirtyEF1Filter dirtyEF2Detergent overdosingEF3Aqua Control system activatedEF4No signal from flow meter with electro valves switched onEF5Interrupted the spinning phaseEH0Power supply frequency out of limits.EH1Power supply frequency out of limits.EH2Power supply voltage too high.EH3Power supply voltage too low.EHELine Safe relay faulty.EHFLine Safe sensing faulty.
Service modes (10)
- Buzzer Activation/Deactivation1
- Cancel Last Alarm1
- Child Safety Activation/DeactivationKeep key 3 and key 2 pressed simultaneously until the LED is lit
- Conductivity adjustment mode["1. Turn the programme selector to switch on the appliance.","2. In selection mode (set-up)…
- Demo Program1
- Diagnostic mode["1. Ensure the appliance is switched OFF (selector at position 0).","2. Switch the appliance ON by…
- Electronic Test1. Switch off the appliance. 2. Hold buttons 4 and 3 pressed simultaneously and turn the program…
- Extra Rinse Activation/Deactivation (hidden)1
- Rapid Alarm Code ReadingKeep buttons 4 and 3 pressed together
- Service Test Program1
Full entry steps, exit procedures, and test sequences are available in Max.