Model reference
KitchenAid KHEV01RSS0
Dryer
3 documents7 error codes4 service modes
Available documentation
Tech Sheet
- TECH SHEET8 pg
Installation Guide
- Instruction Sheet1 pg
- Instruction Sheet2 pg
MyPros+ Max
Diagnose your KitchenAid KHEV01RSS0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (7)
CodeMeaning
E1Temperature sensing circuit is open.E2Temperature sensing circuit is shorted.E3Blower rotational speed dropped below 500 RPM during a cycle; all outputs…E4Tumbler rotational speed dropped to 0 during a cycle; all outputs turned off.E5Dry rack sensor signal lost during a Dry Rack cycle; all outputs turned off.E6Exhaust temperature exceeded 190°F (87.7°C); all outputs turned off.PFPower failure occurred while the dryer was running.Service modes (4)
- Diagnostic Test #1 – Controls Operation["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds, press
- Diagnostic Test #2 – Machine Operation["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 3 seconds, press
- Menu Mode (Factory Calibration / Gas-Electric Toggle)["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 3 seconds, press
- TEST #5a – LED and TouchPad (UI Only Test)["Unplug dryer or disconnect power.","Press and hold the Start and Cycle End Tone buttons.","While…
Full entry steps, exit procedures, and test sequences are available in Max.
Related KitchenAid dryer models
78,000+ service manuals · 160,000+ error codes · 55+ brands