Model reference
KitchenAid KERS505XSS03
Range
4 documents30 error codes15 service modes
Available documentation
Tech Sheet
- Tech Sheet - W1045710516 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Installation Guide
- Installation Instructions20 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your KitchenAid KERS505XSS03.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (30)
CodeMeaning
F1Control failure or UL A/D error(s) detected in the control board.F1 E*Control board failure (all F1 sub-codes indicate control fault).F1-E0EEPROM communication errorF1-E1Upper RTD uncalibratedF1-E2Lower RTD uncalibratedF1-E5Sensor usage out of rangeF1-E7PCB Thermistor/Sensor open or shortedF1-E9WIDE Queue fullF2Shorted/stuck key detected on the control keypad.F2-E0Keypad disconnectedF2-E1Stuck keyF2-E2Stuck keyF3Oven sensor opened or oven sensor shorted.F3 E0Oven temperature sensor fault (open or shorted)F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer temperature sensor fault.F3-E0Main sensor open or shorted (upper oven)F3-E1Main sensor open or shorted (lower oven)F5 E0Door position switch faultF5 E1Door latch switch/system faultF5 E2Door switch fault.F5-E0Door and latch switches do not agree (Clean mode)F5-E1Door latch not operating (Clean mode)F6 E*Control communication failure.F6-E0Lost communicationsF6-E1Over temperature during cook mode (runaway temp)F6-E2Over temperature during clean mode (runaway temp)F6-E3Over temperature in warming drawer (runaway temp)F9House miswiredF9-E0Product is mis-wiredService modes (15)
- Control Reset1
- Diagnostics ModePress CANCEL > CANCEL > START
- Display Test1
- Faults (Error Code Review/Clear)1
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Semi Automatic Test1
- Temperature Calibration1
- Test Mode1
- Usage1
- Version1
Full entry steps, exit procedures, and test sequences are available in Max.