Model reference
LG A4UN306FA0
Air Conditioner
3 documents12 error codes12 service modes
Available documentation
Service Manual
- Multi Air Conditioner SVC MANUAL(Exploded View)124 pg
- Multi Type Room Air Conditioner SERVICE MANUAL139 pg
- Multi Type Room Air Conditioner SVC MANUAL(Exploded View)132 pg
MyPros+ Max
Diagnose your LG A4UN306FA0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (12)
CodeMeaning
1Indoor temperature thermistor open/short or indoor pipe temperature thermistor…10DC low voltage error.11High pressure / Instantaneous power failure.13Overload combination error.14Discharge pipe temperature overheating.2Outdoor temperature thermistor open/short or outdoor pipe temperature…3Wired remote controller communication error.4Drain pump error.5Poor communication between indoor and outdoor unit.7Difference operation8CT / Current error.9DC Peak current error.Service modes (12)
- Forced Operation["Locate the forced operation slide switch on the main unit body.","Switch the slide switch to the…
- Forced Operation (Cassette Type)Press button for 2 seconds to start forced operation.
- forced_operation_cassette_typePress the forced operation button for 2 seconds.
- forced_operation_room_art_cool_typeSet the slide switch on the main unit to the forced operation position while power is on, or supply…
- Test Operation (Cassette Type)["The forced operation is started by pressing button for 2 seconds.","The test run is started by…
- Test Operation (Convertible Type)["Press the forced operation switch for approximately 3 seconds.","The unit operates in cooling…
- Test Operation (Room Type)["Press timer cancel button five times continuously to start the test run."]
- Test Run (Cassette Type)Press button for 5 seconds to start test run.
- Test Run (Room Type)Press the timer cancel button five times continuously.
- test_operation_cassette_typePress the forced operation button for 5 seconds.
- test_operation_convertible_typePress forced operation switch for about 3 seconds.
- test_operation_room_typePress the timer cancel button five times continuously.
Full entry steps, exit procedures, and test sequences are available in Max.
Related LG air conditioner models
75,000+ service documents · 20,000+ error codes · 100+ brands