Model reference

LG A4UW246FA0

Air Conditioner

5 documents30 error codes25 service modes

Available documentation

Service Manual

  • Multi Type Air Conditioner SERVICE MANUAL228 pg
    Covers this model
  • Multi Type Air Conditioner SERVICE MANUAL236 pg
    Covers this model
  • Multi Type Air Conditioner SERVICE MANUAL240 pg
    Covers this model
  • Multi Type Air Conditioner SERVICE MANUAL238 pg
    Covers this model
  • Multi Type Air Conditioner SERVICE MANUAL244 pg
    Covers this model
MyPros+ Max

Diagnose your LG A4UW246FA0.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Service modes (25)

  • Address Monitoring (Wireless Remote)Press Chaos Swing (6) and Reset (13) keys simultaneously.
  • Address Monitoring Mode (Wireless Remote)Press Chaos Swing (6) and Reset (13) keys simultaneously.
  • Address Setting Mode (Wired Remote)Press Program (13) and Set/Clear (16) keys simultaneously for more than 3 seconds
  • Address Setting Mode (Wireless Remote)Press Jet Cool (5) and Reset (13) keys simultaneously for more than 3 seconds
  • address_monitoring_wirelessPress Chaos Swing (6) and Reset (13) keys simultaneously on wireless remote controller.
  • address_setting_wiredPress Program (13) and Set/Clear (16) keys simultaneously for more than 3 seconds on the wired…
  • address_setting_wirelessPress Jet Cool (5) and Reset (13) keys simultaneously for more than 3 seconds on wireless remote…
  • E.S.P. (External Static Pressure) Setting1
  • ESP (External Static Pressure) Setting1
  • ESP Setting Mode (Duct Type Wired Remote)1
  • ESP Setting Mode (Duct/Cassette Wired Remote)1
  • esp_setting_duct1) Push On/Off button to start unit
  • Forced OperationUse the slide switch on the indoor unit main body
  • Forced Operation (Cassette Type)Press the button for 2 seconds to start forced operation.
  • Forced Operation (Slide Switch)Set the slide switch to the forced operation position while power is on, or supply power while…
  • Forced Operation (Split Type via Slide Switch)Set the slide switch to the forced operation position while power is on, or supply power with…
  • forced_operation_cassettePress the forced operation button for 2 seconds on the cassette indoor unit.
  • forced_operation_slide_switchSet the slide switch on the main unit to the forced operation position while power is on, or power…
  • Test Run (Cassette Type)Press the button for 5 seconds to start test run.
  • Test Run (Cassette Wired Remote)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
  • Test Run (CST Wired Remote)Press the Room Temperature Checking button and Down Timer button simultaneously for 3 seconds.
  • Test Run (Room Type)Press the timer cancel button five times continuously.
  • test_run_cassettePress the forced operation button for 5 seconds on the cassette type indoor unit.
  • test_run_cassette_wired_remoconPress the room temperature checking button and down timer button simultaneously for 3 seconds on…
  • test_run_room_typePress the Timer Cancel button five times continuously on the remote controller.

Full entry steps, exit procedures, and test sequences are available in Max.